{"id":9836611971,"title":"Safe-T-Beam® Sensors","handle":"safe-t-beam-sensors","description":"\u003cp\u003eGenies Safe-T-Beam system is designed to ensure maximum safety for your garage door opener operation. Using an invisible infrared beam across the opening of the door, the Genie garage door sensor detects any object passing through the LED beam of light and automatically reverses the closing garage door, keeping children and pets safe.\u003c\/p\u003e\n\u003cp\u003eIf your Safe-T-Beam system has been damaged, a replacement kit is essential to continue safe operation of your garage door opener. This kit is compatible with Genie-only garage door openers manufactured since 1993 that use required safety beams. \u003c\/p\u003e\n\u003cp\u003eOnce installed, your replacement Safe-T-Beams are self-diagnostic and will alert you in the event of any malfunction. Don’t leave safety up to chance – replace your safety beams with this kit today.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReplacement Kit. Replaces broken or faulty safety beams in your Genie garage door opener’s Safe-T-Beam system.\u003c\/li\u003e\n\u003cli\u003eWorks with Many Genie Openers. Compatible with Genie (only) garage door openers manufactured since 1993 that utilize required safety beams.\u003c\/li\u003e\n\u003cli\u003eKeeps Family and Pets Safe. Places an invisible infrared beam across the door opening and reverses door automatically if an object passes through the LED beam of light.\u003c\/li\u003e\n\u003cli\u003eSelf-Diagnostic. Alerts you of any malfunction in installation or operation, as an additional safety measure.\u003c\/li\u003e\n\u003cli\u003eEasy Installation. Replacement kit is easy to install, with mounting brackets and hardware included \u003cspan\u003e(does not include bell wire).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eEquivalent to Genie part numbers 37334R and 37220R\u003c\/li\u003e\n\u003cli\u003eOften Referred to as garage door opener-  photo eyes, electric eyes, safety eyes, and safety sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e  \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003ca href=\"https:\/\/store.geniecompany.com\/pages\/proposition-65\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/trianglewarning_icon.jpg?v=1529498861\" alt=\"\" width=\"19\" height=\"19\"\u003e California\u003cspan\u003e Residents: \u003c\/span\u003eProposition 65 WARNING\u003c\/a\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c!-- TABS --\u003e\n\u003ch5\u003eReviews\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eInstallation Instructions\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/safetbeam.pdf?7882351353251902900\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/PDF_ICON_icon.png?v=1533737947\" alt=\"\"\u003e PDF Installation instructions for installing the Safe-T-Beams\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstalling the 37220R Replacement Safe-T-Beam System\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. IMPORTANT INFORMATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eWARNING\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eMoving Door can cause serious injury or death.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Wall control must be mounted in sight of garage door, at least 5 feet above floor and clear of moving parts.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Keep people clear of opening while door is moving.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Do Not allow children to play with remote or door opener.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eIf Safety Reverse does not work properly:\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Close door, then disconnect opener using manual release handle.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Do Not use remote or door opener.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Refer to Door and Door Opener Owner’s Manuals before attempting any repairs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eElectrical Shock can cause serious injury or death.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Power cord must be unplugged before attaching any wires.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Be sure wire ends do not touch each other or other terminals.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003eIf you have questions or if you need a manual, contact the distributor or manufacturer of the opener.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. MOUNTING SOURCE \u0026amp; SENSOR\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLocations of existing units can be reused if that is desired. Safe-T-Beam® System (STB) Source and Sensor do not have to be mounted on garage door frame. They can be placed anywhere along garage door wall that is convenient for mounting, provided the location meets the following requirements:\u003cbr\u003e1) They must be placed across the door opening,\u003cbr\u003e2) at the proper height,\u003cbr\u003e3) with a clear line of sight between them. (Max. Range is 30 feet).\u003cbr\u003e(They may be mounted on the floor, only as a last resort, if there is\u003cbr\u003eno other option. Not recommended.)\u003c\/p\u003e\n\u003cp\u003e1. To ease mounting, source and sensor units can be detached from the bracket by pulling them apart. After mounting brackets, slide units back onto brackets.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_Step_1_medium.png?v=1559219958\" alt=\"Installing Genie Safe-T-Beams replacements instructions Step 1 \"\u003e\u003c\/p\u003e\n\u003cp\u003e2. Ensure there will be an unobstructed path between source and sensor. Sensor should be mounted on the side of the garage door opening that receives the least direct sunlight.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_Step_2_medium.png?v=1559220038\" alt=\"Step 2 Replacing the Genie garage door opener Safe-T-Beam system\"\u003e\u003c\/p\u003e\n\u003cp\u003e3. Once the location is established, measure the height of bracket as shown. Hold the bracket in place and mark hole locations. 1\/8\" pilot holes are recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_Step_3_medium.png?v=1559220101\" alt=\"Installation of Safe-T-Beams for Genie garage door openers Height instructions\"\u003e\u003c\/p\u003e\n\u003cp\u003e*No height adjustment is needed for units mounted on floor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. WIRE RUN\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReuse of existing wiring is easiest and recommended unless it is broken, cut, frayed or there is a problem. If you can reuse existing wiring — SKIP FORWARD TO STEP 4. If new wiring must be installed, the path shown below is recommended.\u003c\/p\u003e\n\u003cp\u003e1. Route two (2) lengths of two (2) conductor wire (See above) from opener, along top of rail.\u003cbr\u003eFasten wire to rail.\u003cbr\u003e— Evenly space fasteners along rail.\u003cbr\u003eFasten to header and wall (preferably with insulated staples). Allow for some slack at the source and sensor units and cut off any excess wire.\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_Wire_Run_medium.png?v=1559220300\" alt=\"Genie replacement Safe-T-Beams installing the wiring \"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eCAUTION: When using insulated staples, be aware that staples which are too tight can cut or pinch wires. Cut or pinched wires can cause the Safe-T-Beam® System to stop working. When using insulated staples, make sure you fasten them only as tightly as needed to hold the wire snugly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e2. At source and sensor, route wires through bracket as shown and attach wires at terminals. Either wire to either terminal (non-polar).\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_No_Polarity_medium.png?v=1559220387\" alt=\"Genie 37220R Safe-T-Beam replacement wiring \"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e3. If installing new wiring:\u003cbr\u003eAt opener, twist striped wires together. Twist plain wires together. Feed down through control wire tube “chimney” at top of opener.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_wire_tube_medium.png?v=1559220529\" alt=\"Genie garage door opener power head Wire tube for Safe-T-Beam wiring \"\u003e\u003c\/p\u003e\n\u003cp\u003e4. Attach to terminals #1 and #2 (again either wire). Bundle excess wire and tape to top of power head.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_terminals_medium.png?v=1559220587\" alt=\"Genie replacement Safe-T-Beam system wiring to the terminals \"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. SAFE-T-BEAM® SYSTEM TEST\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSafe-T-Beam® System must be installed and working properly in order for door opener to function.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eCAUTION: During testing of the Safe-T-Beam® System, be sure to stay clear of the door and any moving parts. It is preferable to use a long-handled object to interrupt the beam during tests.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e1. Start door moving in close direction.\u003c\/p\u003e\n\u003cp\u003e2. Pass an object through the path of the Safe-T-Beam® System in order to interrupt beam.\u003cbr\u003e— Door should stop and reverse direction to fully open position.\u003c\/p\u003e\n\u003cp\u003eIf door will not run in closed direction, check for these or see chart below:\u003cbr\u003e• Misalignment of Safe-T-Beam® System (Red LED on source unit will be blinking).\u003cbr\u003e• Obstruction in path of beam.\u003cbr\u003e• Pinched or broken wire.\u003cbr\u003e• Loose wiring connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTroubleshooting Guide \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGenie Safe-T-Beam System Self Diagnostic Troubleshooting \u003c\/p\u003e\n\u003ctable style=\"width: 536px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003eSource (RED LED) \u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eSource (Green LED)\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003ePossible Problem \u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003eSolution \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003eNormal Operation \u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003eNone Required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003eOFF\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eOFF\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e\n\u003cp\u003e•Powerhead not powered \u003c\/p\u003e\n\u003cp\u003e•Wiring from Powerhead bad\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e\n\u003cp\u003e•Check breakers, fuses, plugs\u003c\/p\u003e\n\u003cp\u003e•Check wiring for obvoious shorts \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003eOFF\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e\n\u003cp\u003e•Wiring to source missing or bad\u003c\/p\u003e\n\u003cp\u003e•Power has been interrupted\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e•Check Wiring                                  •Remove power and reapply \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003e2 Blinks, Pause (Repeat)\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e\n\u003cp\u003e•Beam not aligned                   \u003c\/p\u003e\n\u003cp\u003e•Beam obstructed                   •Sensor defective \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e\n\u003cp\u003e•Check Source, sensor alignment\u003c\/p\u003e\n\u003cp\u003e•Check for obstruction          \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003e2 Blinks, Pause (Repeat)\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eOFF\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e\n\u003cp\u003e•Wire to sensor missing or bad\u003c\/p\u003e\n\u003cp\u003e•Sensor defective\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e•Check Wiring                             \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003e3 Blinks, Pause (Repeat)\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e•Sensor receiving interference\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e•Find source of interference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003e3 Blinks, Pause (Repeat)\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e\n\u003cp\u003e•Source not sending pulses\u003c\/p\u003e\n\u003cp\u003e•Source defective \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e•Contact Customer service \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIf you still have a problem, contact Customer Service at 1-800-35-GENIE.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_warning_medium.png?v=1559220809\" alt=\"Safe-T-Beam Warning \"\u003e\u003c\/p\u003e\n\u003cp\u003eORDERING INFO:\u003cbr\u003eTo order wire use the following part numbers:\u003c\/p\u003e\n\u003cp\u003eSafe-T-Beam wiring- part number \u003ca href=\"https:\/\/store.geniecompany.com\/collections\/wire-wire-clips\/products\/bell-wire\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e35265A.S and 35265B.S\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/store.geniecompany.com\/collections\/wire-wire-clips\/products\/bell-wire\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_wire_ordering_medium.png?v=1559220848\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDiagnostic Troubleshooting\u003c\/h5\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/stbdiagnostic2.jpg?6638189643415955466\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"Genie Safe-T-Beam System Self Diagnostic troubleshooting Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/stbdiagnostic2_large.jpg?v=1531249174\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSafe-T-Beam technology uses a continuous infrared \u003c\/span\u003e\u003cem class=\"rn_Highlight\"\u003ebeam\u003c\/em\u003e\u003cspan\u003e that projects across the interior of the garage door opening to a receiver at all times. In order for your garage door to operate, the \u003c\/span\u003e\u003cem class=\"rn_Highlight\"\u003ebeam\u003c\/em\u003e\u003cspan\u003e must be located at least five inches, but no more than six inches, from the floor, and it should be aligned so that the sensors “see” each other. During closing, if the \u003c\/span\u003e\u003cem class=\"rn_Highlight\"\u003ebeam\u003c\/em\u003e\u003cspan\u003e is interrupted by a person, animal or object, Safe-T-Beam automatically raises the garage door to protect whatever is in its path. Please note that the garage door opener will not close the door unless Safe-T-Beam® is installed and working properly.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- \/TABS --\u003e","published_at":"2017-04-26T16:21:53-04:00","created_at":"2017-04-03T15:51:25-04:00","vendor":"The Genie Company","type":"Sensors","tags":["Safety Beams"],"price":4199,"price_min":4199,"price_max":4199,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":36157483907,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"37220R","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Safe-T-Beam® Sensors","public_title":null,"options":["Default Title"],"price":4199,"weight":227,"compare_at_price":null,"inventory_quantity":998,"inventory_management":"shopify","inventory_policy":"continue","barcode":"050049017514"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/products\/37334R-04.jpg?v=1558531778","\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/products\/Untitled_design.png?v=1558531778","\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/products\/Genie_GSTB-R.gif?v=1558531778","\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/products\/beams_with_bike.jpg?v=1558531778","\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/products\/Safety-Beams_84e8e48d-62c1-4a1a-8c8e-c2b2f424ccde.jpg?v=1558531778"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/products\/37334R-04.jpg?v=1558531778","options":["Title"],"content":"\u003cp\u003eGenies Safe-T-Beam system is designed to ensure maximum safety for your garage door opener operation. Using an invisible infrared beam across the opening of the door, the Genie garage door sensor detects any object passing through the LED beam of light and automatically reverses the closing garage door, keeping children and pets safe.\u003c\/p\u003e\n\u003cp\u003eIf your Safe-T-Beam system has been damaged, a replacement kit is essential to continue safe operation of your garage door opener. This kit is compatible with Genie-only garage door openers manufactured since 1993 that use required safety beams. \u003c\/p\u003e\n\u003cp\u003eOnce installed, your replacement Safe-T-Beams are self-diagnostic and will alert you in the event of any malfunction. Don’t leave safety up to chance – replace your safety beams with this kit today.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReplacement Kit. Replaces broken or faulty safety beams in your Genie garage door opener’s Safe-T-Beam system.\u003c\/li\u003e\n\u003cli\u003eWorks with Many Genie Openers. Compatible with Genie (only) garage door openers manufactured since 1993 that utilize required safety beams.\u003c\/li\u003e\n\u003cli\u003eKeeps Family and Pets Safe. Places an invisible infrared beam across the door opening and reverses door automatically if an object passes through the LED beam of light.\u003c\/li\u003e\n\u003cli\u003eSelf-Diagnostic. Alerts you of any malfunction in installation or operation, as an additional safety measure.\u003c\/li\u003e\n\u003cli\u003eEasy Installation. Replacement kit is easy to install, with mounting brackets and hardware included \u003cspan\u003e(does not include bell wire).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eEquivalent to Genie part numbers 37334R and 37220R\u003c\/li\u003e\n\u003cli\u003eOften Referred to as garage door opener-  photo eyes, electric eyes, safety eyes, and safety sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e  \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003ca href=\"https:\/\/store.geniecompany.com\/pages\/proposition-65\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/trianglewarning_icon.jpg?v=1529498861\" alt=\"\" width=\"19\" height=\"19\"\u003e California\u003cspan\u003e Residents: \u003c\/span\u003eProposition 65 WARNING\u003c\/a\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c!-- TABS --\u003e\n\u003ch5\u003eReviews\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eInstallation Instructions\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/safetbeam.pdf?7882351353251902900\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/PDF_ICON_icon.png?v=1533737947\" alt=\"\"\u003e PDF Installation instructions for installing the Safe-T-Beams\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstalling the 37220R Replacement Safe-T-Beam System\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. IMPORTANT INFORMATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eWARNING\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eMoving Door can cause serious injury or death.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Wall control must be mounted in sight of garage door, at least 5 feet above floor and clear of moving parts.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Keep people clear of opening while door is moving.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Do Not allow children to play with remote or door opener.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eIf Safety Reverse does not work properly:\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Close door, then disconnect opener using manual release handle.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Do Not use remote or door opener.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Refer to Door and Door Opener Owner’s Manuals before attempting any repairs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eElectrical Shock can cause serious injury or death.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Power cord must be unplugged before attaching any wires.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Be sure wire ends do not touch each other or other terminals.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003eIf you have questions or if you need a manual, contact the distributor or manufacturer of the opener.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. MOUNTING SOURCE \u0026amp; SENSOR\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLocations of existing units can be reused if that is desired. Safe-T-Beam® System (STB) Source and Sensor do not have to be mounted on garage door frame. They can be placed anywhere along garage door wall that is convenient for mounting, provided the location meets the following requirements:\u003cbr\u003e1) They must be placed across the door opening,\u003cbr\u003e2) at the proper height,\u003cbr\u003e3) with a clear line of sight between them. (Max. Range is 30 feet).\u003cbr\u003e(They may be mounted on the floor, only as a last resort, if there is\u003cbr\u003eno other option. Not recommended.)\u003c\/p\u003e\n\u003cp\u003e1. To ease mounting, source and sensor units can be detached from the bracket by pulling them apart. After mounting brackets, slide units back onto brackets.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_Step_1_medium.png?v=1559219958\" alt=\"Installing Genie Safe-T-Beams replacements instructions Step 1 \"\u003e\u003c\/p\u003e\n\u003cp\u003e2. Ensure there will be an unobstructed path between source and sensor. Sensor should be mounted on the side of the garage door opening that receives the least direct sunlight.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_Step_2_medium.png?v=1559220038\" alt=\"Step 2 Replacing the Genie garage door opener Safe-T-Beam system\"\u003e\u003c\/p\u003e\n\u003cp\u003e3. Once the location is established, measure the height of bracket as shown. Hold the bracket in place and mark hole locations. 1\/8\" pilot holes are recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_Step_3_medium.png?v=1559220101\" alt=\"Installation of Safe-T-Beams for Genie garage door openers Height instructions\"\u003e\u003c\/p\u003e\n\u003cp\u003e*No height adjustment is needed for units mounted on floor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. WIRE RUN\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReuse of existing wiring is easiest and recommended unless it is broken, cut, frayed or there is a problem. If you can reuse existing wiring — SKIP FORWARD TO STEP 4. If new wiring must be installed, the path shown below is recommended.\u003c\/p\u003e\n\u003cp\u003e1. Route two (2) lengths of two (2) conductor wire (See above) from opener, along top of rail.\u003cbr\u003eFasten wire to rail.\u003cbr\u003e— Evenly space fasteners along rail.\u003cbr\u003eFasten to header and wall (preferably with insulated staples). Allow for some slack at the source and sensor units and cut off any excess wire.\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_Wire_Run_medium.png?v=1559220300\" alt=\"Genie replacement Safe-T-Beams installing the wiring \"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eCAUTION: When using insulated staples, be aware that staples which are too tight can cut or pinch wires. Cut or pinched wires can cause the Safe-T-Beam® System to stop working. When using insulated staples, make sure you fasten them only as tightly as needed to hold the wire snugly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e2. At source and sensor, route wires through bracket as shown and attach wires at terminals. Either wire to either terminal (non-polar).\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_No_Polarity_medium.png?v=1559220387\" alt=\"Genie 37220R Safe-T-Beam replacement wiring \"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e3. If installing new wiring:\u003cbr\u003eAt opener, twist striped wires together. Twist plain wires together. Feed down through control wire tube “chimney” at top of opener.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_wire_tube_medium.png?v=1559220529\" alt=\"Genie garage door opener power head Wire tube for Safe-T-Beam wiring \"\u003e\u003c\/p\u003e\n\u003cp\u003e4. Attach to terminals #1 and #2 (again either wire). Bundle excess wire and tape to top of power head.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_terminals_medium.png?v=1559220587\" alt=\"Genie replacement Safe-T-Beam system wiring to the terminals \"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. SAFE-T-BEAM® SYSTEM TEST\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSafe-T-Beam® System must be installed and working properly in order for door opener to function.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eCAUTION: During testing of the Safe-T-Beam® System, be sure to stay clear of the door and any moving parts. It is preferable to use a long-handled object to interrupt the beam during tests.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e1. Start door moving in close direction.\u003c\/p\u003e\n\u003cp\u003e2. Pass an object through the path of the Safe-T-Beam® System in order to interrupt beam.\u003cbr\u003e— Door should stop and reverse direction to fully open position.\u003c\/p\u003e\n\u003cp\u003eIf door will not run in closed direction, check for these or see chart below:\u003cbr\u003e• Misalignment of Safe-T-Beam® System (Red LED on source unit will be blinking).\u003cbr\u003e• Obstruction in path of beam.\u003cbr\u003e• Pinched or broken wire.\u003cbr\u003e• Loose wiring connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTroubleshooting Guide \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGenie Safe-T-Beam System Self Diagnostic Troubleshooting \u003c\/p\u003e\n\u003ctable style=\"width: 536px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003eSource (RED LED) \u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eSource (Green LED)\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003ePossible Problem \u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003eSolution \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003eNormal Operation \u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003eNone Required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003eOFF\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eOFF\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e\n\u003cp\u003e•Powerhead not powered \u003c\/p\u003e\n\u003cp\u003e•Wiring from Powerhead bad\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e\n\u003cp\u003e•Check breakers, fuses, plugs\u003c\/p\u003e\n\u003cp\u003e•Check wiring for obvoious shorts \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003eOFF\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e\n\u003cp\u003e•Wiring to source missing or bad\u003c\/p\u003e\n\u003cp\u003e•Power has been interrupted\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e•Check Wiring                                  •Remove power and reapply \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003e2 Blinks, Pause (Repeat)\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e\n\u003cp\u003e•Beam not aligned                   \u003c\/p\u003e\n\u003cp\u003e•Beam obstructed                   •Sensor defective \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e\n\u003cp\u003e•Check Source, sensor alignment\u003c\/p\u003e\n\u003cp\u003e•Check for obstruction          \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003e2 Blinks, Pause (Repeat)\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eOFF\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e\n\u003cp\u003e•Wire to sensor missing or bad\u003c\/p\u003e\n\u003cp\u003e•Sensor defective\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e•Check Wiring                             \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003e3 Blinks, Pause (Repeat)\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e•Sensor receiving interference\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e•Find source of interference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003e3 Blinks, Pause (Repeat)\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e\n\u003cp\u003e•Source not sending pulses\u003c\/p\u003e\n\u003cp\u003e•Source defective \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e•Contact Customer service \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIf you still have a problem, contact Customer Service at 1-800-35-GENIE.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_warning_medium.png?v=1559220809\" alt=\"Safe-T-Beam Warning \"\u003e\u003c\/p\u003e\n\u003cp\u003eORDERING INFO:\u003cbr\u003eTo order wire use the following part numbers:\u003c\/p\u003e\n\u003cp\u003eSafe-T-Beam wiring- part number \u003ca href=\"https:\/\/store.geniecompany.com\/collections\/wire-wire-clips\/products\/bell-wire\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e35265A.S and 35265B.S\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/store.geniecompany.com\/collections\/wire-wire-clips\/products\/bell-wire\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_wire_ordering_medium.png?v=1559220848\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDiagnostic Troubleshooting\u003c\/h5\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/stbdiagnostic2.jpg?6638189643415955466\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"Genie Safe-T-Beam System Self Diagnostic troubleshooting Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/stbdiagnostic2_large.jpg?v=1531249174\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSafe-T-Beam technology uses a continuous infrared \u003c\/span\u003e\u003cem class=\"rn_Highlight\"\u003ebeam\u003c\/em\u003e\u003cspan\u003e that projects across the interior of the garage door opening to a receiver at all times. In order for your garage door to operate, the \u003c\/span\u003e\u003cem class=\"rn_Highlight\"\u003ebeam\u003c\/em\u003e\u003cspan\u003e must be located at least five inches, but no more than six inches, from the floor, and it should be aligned so that the sensors “see” each other. During closing, if the \u003c\/span\u003e\u003cem class=\"rn_Highlight\"\u003ebeam\u003c\/em\u003e\u003cspan\u003e is interrupted by a person, animal or object, Safe-T-Beam automatically raises the garage door to protect whatever is in its path. Please note that the garage door opener will not close the door unless Safe-T-Beam® is installed and working properly.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- \/TABS --\u003e"}
Genie garage door opener replacement Safe-T-Beams, safety eyes part number 37220R

Safe-T-Beam® Sensors

$41.99

Genies Safe-T-Beam system is designed to ensure maximum safety for your garage door opener operation. Using an invisible infrared beam across the opening of the door, the Genie garage door sensor detects any object passing through the LED beam of light and automatically reverses the closing garage door, keeping children and pets safe. If your Sa...


More Info