The Genie battery backup unit offers peace-of-mind to homeowners who need to be able to operate their garage door opener during a power outage. When the power goes out, Genie power goes on automatically. Never be locked out of your garage again due to bad weather or electric company equipment failure. This garage door opener battery backup add on allows for up to 50 full operations of your garage door when the primary power is out. This backup is designed specifically for the Genie 140 volt garage door openers. 

  • Optional accessory for Genie 140 volt models- PowerMax1500, PowerMax1200, SilentMax1200, SilentMax1000, ChainMax1000, MachForce, Excelerator II or TriloG and IntelliG - Model numbers 3022, 3024, 3042, 4022, 4024, 4042, 3062, 3064, 4062, 4063, 4064. **
  • Provides up to 50 cycles after the main power outage
  • Color-coded LEDs on the front of the battery unit show charge status
  •  3' connector cable between the opener and battery back-up unit is included
  • Includes 1 battery, mounting bracket, 2 screws, and connecter cable
  • Automatically recharges during normal garage door function and kicks into action automatically when the main power is lost
  • Replaces part number 37228R

**Compatible models with serial numbers that begin with 12249 or lower cannot add this battery backup as an option.

 California Residents: Proposition 65 WARNING

SKU: 41590R

In Stock! Usually ships within 24 hours.

ASK A QUESTION View full details
Genie Garage Door Opener Battery Backup_41590R
Battery Backup for 140V Motors - 41590R
$110.00

QUESTIONS & ANSWERS

Ask a Question
  • Can this battery backup work on the silent max 3053-tsv model? If not, is there another battery backup option? Thanks

    No, sorry the 3053 model is not compatible with a battery back up unit.

  • I have a professional line model 2028 that came with the house I just purchased. Is this compatible with the model 2028?

    No, the 2028 is not compatible with any battery backup unit.

  • Is there a battery backup option available that will work with Model 1035?

    No, sorry there is no battery backup option for the Genie model 1035.

  • I have the chain drive 500 opener, model 1035. Is this battery backup compatible with my opener. I do not see that model listed.

    No sorry, the battery backup is not compatible with Genie model 1035.

  • I have a professional line model 4124 that came with the house I just purchased. This opener says it can use a battery backup, but I can’t find if this is the correct one. Is this compatible with the model 4124?

    Yes, the Battery Backup for 140V Motors is the correct battery back up for your model 4124.

  • 1/2 hp screw drive G5050, can I add a battery backup?

    No, there is not a battery backup compatible with the G5050.

  • wil this work with my GPS1200IC Genie Pro Stealth garage door opener. (Battery backup 41590R? Thank you

    No, the Battery Backup for 140V Motors - 41590R will not work on the GPS1200IC garage door opener. We do not have a battery backup compatible with that opener.

  • Is there a battery backup for Genie Intellig with serial #121154110665AF? I believe it is model 3024 or 3024H

    The Battery Backup for 140V Motors - 41590R is the correct battery back up for the Genie model 3024 garage door opener. With or without the H.

  • Can this battery backup work on a Machforce 4063-tnmsv.

    Yes, the Battery Backup for 140V Motors - 41590R is compatible with Genie model 4063.

  • Is there a backup battery for model 3055

    Hello. I am sorry but a battery back up is not made for this model of garage door opener.

  • is ther a battery backup for cm8600ic/a

    We do not offer a battery back up that will work with the Genie model CM8600IC/A

PDF Genie Battery Back-Up Replacement Instructions 

Battery Back-Up for Residential Garage Door Openers

BATTERY BACK-UP INSTALLATION OR REPLACEMENT INSTRUCTIONS

* READ AND FOLLOW ALL SAFETY WARNINGS, CAUTIONS AND THESE ENTIRE INSTRUCTIONS PRIOR TO BEGINNING!

To Prevent possible Serious Injury or Death by Electrocution -Disconnect all electric power sources and battery power BEFORE performing ANY service or maintenance. INSTALL ONLY IN DRY LOCATIONS. NOT FOR OUTDOOR USE.

This unit to be used ONLY with Genie® Operator Models PowerMax®, SC, TriloG™, PowerLift™, SilentMax®, CB and IntelliG® that are equipped with Series II electronics. Disconnect power before performing the following tasks. Do NOT drill holes in the Battery Back-Up case.

To Reduce the Risk of Fire or Injury to Persons  A. Use only the following type and size battery 12V, 8Ah (Genie® P/N 37342R). B. Do not install Battery Back-up unit on an improperly balanced door. An unbalanced door could cause severe injury or damage to this unit. Repairs and adjustments to the door must be made by trained service persons using proper tools and instructions. C. Do not dispose of the battery in fire. The cells may explode. Check with local codes for possible disposal instructions. D. Do not open or mutilate the battery. Released electrolyte is corrosive and can damage eyes or skin.TOXIC if swallowed. E. Exercise care in handling the battery to prevent shorting battery with conducting materials such as rings, bracelets & keys. F. Change the battery provided with or identified for use with this product only in accordance with the instructions and limitations specified in this instruction. G. Observe proper polarity orientation between the battery and charging circuit. H . Do not set limits while in Battery Back-up Mode. AC power MUST be connected to the opener, while setting limits, for proper operation

REQUIREMENTS This unit is designed to work with specific garage door openers on properly balanced doors with a maximum height of 8 ft. and a maximum weight of 500 lb. The unit will provide operation of the door for 24 hours after a power loss. Your garage door opener MUST have the matching Connection Cable connector in the powerhead. Do not tamper with or rewire Connection Cable. The unit may be wall mounted provided mounting location is within 24 inches of the powerhead. The unit must be inserted into the mounting bracket as far as it will go so that the bracket locks onto the ridges (Figure at Top Right) on top of the Battery Back-Up unit. This prevents the unit from moving. The unit must be mounted so that the Status LEDs are visible from the floor, and it is locked into the mounting bracket.

INSTALLATION

NOTE: DO NOT connect the Battery Back-Up Connection Cable to the garage door opener until you have completed Steps 1 & 2.

Step 1. Wire Battery 

A. Remove Cover (4 screws).

— Remove foam shipping block and throw away.

 B. Connect RED (+) wire to RED terminal, BLACK (–) wire to BLACK terminal.

NOTE: DO NOT REVERSE CONNECTIONS—this WILL damage the Battery Back-Up Unit.

C. Replace Cover. 

Step 2. Mount

Choose mounting, Method 1 - Ceiling Mount Method 2 Angle Iron Mount and Method 3 - Horizontal Mount and attach the mounting plate using screws provided.

Method 1 - Ceiling Mount Locate and attach the mounting plate to ceiling rafter or truss using two 5/16" x 1-3/4" lag screws (provided). — Drill 3/16" pilot holes for lag screws.

Method 2 - Angle Iron Mount

A. Fasten a second perforated angle iron (not provided) to the powerhead mounting angle iron as shown using two 5/16" nuts and bolts (not provided).

B. Attach the mounting plate to the perforated angle iron using two more 5/16" nuts and bolts (not provided).

Method 3 - Horizontal Mount

A. ENSURE the locking TABS are at the bottom and attach the mounting plate with (2) two 5/16" x 1-1/2" lag screws.

B. Plug the Connection Cable into the Battery Back-Up unit.

C. Slide the Battery Back-Up unit into the mounting plate. 

 

Step 3. Wiring to powerhead

A. Remove power from garage door opener (unplug or turn off the breaker).

B. Remove the connector port cover for the Battery Back-Up (marked "BBU") on the Powerhead

C. Plug the Connection Cable into the operator powerhead Battery Back-Up port.

D. Restore power to the garage door opener. 

E. Battery Back-Up will NOT turn on until the opener has power.

Step 4. Testing

NOTE: It is recommended that the battery be allowed to charge for 24 to 48 hours prior to initial testing. Initially, the opener may not run in the Battery Back-Up mode if the battery charge is too low.

A. Run the opener using the Wall Console or Remote Transmitter to ensure it is working properly.

A. Turn off power to the garage door opener by unplugging its power cord from its grounded outlet, or turn off the breaker in the permanently installed power circuit.

B. Press the OPEN/CLOSE button on the wall control to operate the opener. It should operate the door at a lower speed.

NOTE: If the opener does not operate, recheck the connections of the Connection Cable at both the powerhead and the Battery Back-Up and try again, (SEE CAUTION BELOW.)

C. After successfully completing the test, return power to the garage door opener

REMINDER: Battery Back-Up will not turn on until power is restored to the opener

CAUTION: To remove the Connection Cable connector from the Battery Back-Up port on the powerhead, you must depress the disconnect latch before pulling the connector out of the port. Use a small screwdriver or similar device. Attempting to remove the connector without first depressing the latch will damage the circuit board

OPERATION

No user required tasks for normal use. The opener will run at a slower speed while using battery power

There are three (3) LEDs on the front housing; GREEN, YELLOW, and RED. Use the CHART.

COLOR INDICATION ACTION REQUIRED

Green LED Normal operation, No action required

Yellow LED Battery is charging, No action required

Red LED Battery voltage is below operational level. If the red LED stays on over 48 hours, the battery has failed to charge. Check Connection Cable connections and battery.

NOTE: Remember when replacing the battery—DO NOT REVERSE POLARITY [(+) and (–)] as this WILL damage the circuit board.

NOTE: To conserve battery power during a power failure (in Battery Back-Up mode), the motion detector & work light will not function.

BATTERY REPLACEMENT* SEE BELOW

A. Remove power to the opener (unplug or turn off the breaker) and unplug Connection Cable from Battery Back-Up.

B. Slide unit out of the mounting bracket.

C. Remove cover (4 screws).

D. Slide connectors off the battery.

E. Remove the old battery and insert its replacement.

F. Attach connectors, RED (+) and BLACK (–), to battery terminals.

G. Replace cover (4 screws).

H Slide unit onto the mounting bracket.

I. Plug in Connection Cable.

J . Plug in power cord. 

* BE SURE YOU READ AND FOLLOW ALL SAFETY WARNINGS & CAUTIONS PRIOR TO PERFORMING THESE INSTRUCTIONS!

  • Shipping Truck

    Free Shipping

    We offer FREE shipping and handling on all orders that total over $17.99 and are shipped to a US address. All orders are shipped using UPS ground, directly from The Genie Company.

  • Genuine Genie Accessories and Parts

    Genuine Replacements

    Buying GENUINE Genie accessories and parts guarantees that you are getting quality OEM materials backed by a Genie warranty.

  • Customer support chat

    Support

    Need assistance? We are here for you! We offer a wide range of customer support options including contact by phone or email, web chat services with a live agent, and a robust support section also located on our website.  All customer care teams and services are based in the USA.

FREE SHIPPING ON ALL US ORDERS 17.99 AND UP