{"id":9836611971,"title":"Safe-T-Beam® Sensors","handle":"safe-t-beam-sensors","description":"\u003cp\u003eGenies Safe-T-Beam system is designed to ensure maximum safety for your garage door opener operation. Using an invisible infrared beam across the opening of the door, the Genie garage door sensor detects any object passing through the LED beam of light and automatically reverses the closing garage door, keeping children and pets safe.\u003c\/p\u003e\n\u003cp\u003eIf your Safe-T-Beam system has been damaged, a replacement kit is essential to continue safe operation of your garage door opener. This kit is compatible with Genie-only garage door openers manufactured since 1993 that use required safety beams. \u003c\/p\u003e\n\u003cp\u003eOnce installed, your replacement Safe-T-Beams are self-diagnostic and will alert you in the event of any malfunction. Don’t leave safety up to chance – replace your safety beams with this kit today.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReplacement Kit. Replaces broken or faulty safety beams in your Genie garage door opener’s Safe-T-Beam system.\u003c\/li\u003e\n\u003cli\u003eWorks with Many Genie Openers. Compatible with Genie (only) garage door openers manufactured since 1993 that utilize required safety beams.\u003c\/li\u003e\n\u003cli\u003eKeeps Family and Pets Safe. Places an invisible infrared beam across the door opening and reverses door automatically if an object passes through the LED beam of light.\u003c\/li\u003e\n\u003cli\u003eSelf-Diagnostic. Alerts you of any malfunction in installation or operation, as an additional safety measure.\u003c\/li\u003e\n\u003cli\u003eEasy Installation. Replacement kit is easy to install, with mounting brackets and hardware included \u003cspan\u003e(does not include bell wire).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eEquivalent to Genie part numbers 37334R and 37220R\u003c\/li\u003e\n\u003cli\u003eOften Referred to as garage door opener-  photo eyes, electric eyes, safety eyes, and safety sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e  \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003ca href=\"https:\/\/store.geniecompany.com\/pages\/proposition-65\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/trianglewarning_icon.jpg?v=1529498861\" alt=\"\" width=\"19\" height=\"19\"\u003e California\u003cspan\u003e Residents: \u003c\/span\u003eProposition 65 WARNING\u003c\/a\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c!-- TABS --\u003e\n\u003ch5\u003eReviews\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eInstallation Instructions\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/safetbeam.pdf?7882351353251902900\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/PDF_ICON_icon.png?v=1533737947\" alt=\"\"\u003e PDF Installation instructions for installing the Safe-T-Beams\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstalling the 37220R Replacement Safe-T-Beam System\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. IMPORTANT INFORMATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eWARNING\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eMoving Door can cause serious injury or death.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Wall control must be mounted in sight of garage door, at least 5 feet above floor and clear of moving parts.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Keep people clear of opening while door is moving.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Do Not allow children to play with remote or door opener.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eIf Safety Reverse does not work properly:\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Close door, then disconnect opener using manual release handle.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Do Not use remote or door opener.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Refer to Door and Door Opener Owner’s Manuals before attempting any repairs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eElectrical Shock can cause serious injury or death.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Power cord must be unplugged before attaching any wires.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Be sure wire ends do not touch each other or other terminals.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003eIf you have questions or if you need a manual, contact the distributor or manufacturer of the opener.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. MOUNTING SOURCE \u0026amp; SENSOR\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLocations of existing units can be reused if that is desired. Safe-T-Beam® System (STB) Source and Sensor do not have to be mounted on garage door frame. They can be placed anywhere along garage door wall that is convenient for mounting, provided the location meets the following requirements:\u003cbr\u003e1) They must be placed across the door opening,\u003cbr\u003e2) at the proper height,\u003cbr\u003e3) with a clear line of sight between them. (Max. Range is 30 feet).\u003cbr\u003e(They may be mounted on the floor, only as a last resort, if there is\u003cbr\u003eno other option. Not recommended.)\u003c\/p\u003e\n\u003cp\u003e1. To ease mounting, source and sensor units can be detached from the bracket by pulling them apart. After mounting brackets, slide units back onto brackets.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_Step_1_medium.png?v=1559219958\" alt=\"Installing Genie Safe-T-Beams replacements instructions Step 1 \"\u003e\u003c\/p\u003e\n\u003cp\u003e2. Ensure there will be an unobstructed path between source and sensor. Sensor should be mounted on the side of the garage door opening that receives the least direct sunlight.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_Step_2_medium.png?v=1559220038\" alt=\"Step 2 Replacing the Genie garage door opener Safe-T-Beam system\"\u003e\u003c\/p\u003e\n\u003cp\u003e3. Once the location is established, measure the height of bracket as shown. Hold the bracket in place and mark hole locations. 1\/8\" pilot holes are recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_Step_3_medium.png?v=1559220101\" alt=\"Installation of Safe-T-Beams for Genie garage door openers Height instructions\"\u003e\u003c\/p\u003e\n\u003cp\u003e*No height adjustment is needed for units mounted on floor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. WIRE RUN\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReuse of existing wiring is easiest and recommended unless it is broken, cut, frayed or there is a problem. If you can reuse existing wiring — SKIP FORWARD TO STEP 4. If new wiring must be installed, the path shown below is recommended.\u003c\/p\u003e\n\u003cp\u003e1. Route two (2) lengths of two (2) conductor wire (See above) from opener, along top of rail.\u003cbr\u003eFasten wire to rail.\u003cbr\u003e— Evenly space fasteners along rail.\u003cbr\u003eFasten to header and wall (preferably with insulated staples). Allow for some slack at the source and sensor units and cut off any excess wire.\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_Wire_Run_medium.png?v=1559220300\" alt=\"Genie replacement Safe-T-Beams installing the wiring \"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eCAUTION: When using insulated staples, be aware that staples which are too tight can cut or pinch wires. Cut or pinched wires can cause the Safe-T-Beam® System to stop working. When using insulated staples, make sure you fasten them only as tightly as needed to hold the wire snugly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e2. At source and sensor, route wires through bracket as shown and attach wires at terminals. Either wire to either terminal (non-polar).\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_No_Polarity_medium.png?v=1559220387\" alt=\"Genie 37220R Safe-T-Beam replacement wiring \"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e3. If installing new wiring:\u003cbr\u003eAt opener, twist striped wires together. Twist plain wires together. Feed down through control wire tube “chimney” at top of opener.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_wire_tube_medium.png?v=1559220529\" alt=\"Genie garage door opener power head Wire tube for Safe-T-Beam wiring \"\u003e\u003c\/p\u003e\n\u003cp\u003e4. Attach to terminals #1 and #2 (again either wire). Bundle excess wire and tape to top of power head.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_terminals_medium.png?v=1559220587\" alt=\"Genie replacement Safe-T-Beam system wiring to the terminals \"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. SAFE-T-BEAM® SYSTEM TEST\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSafe-T-Beam® System must be installed and working properly in order for door opener to function.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eCAUTION: During testing of the Safe-T-Beam® System, be sure to stay clear of the door and any moving parts. It is preferable to use a long-handled object to interrupt the beam during tests.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e1. Start door moving in close direction.\u003c\/p\u003e\n\u003cp\u003e2. Pass an object through the path of the Safe-T-Beam® System in order to interrupt beam.\u003cbr\u003e— Door should stop and reverse direction to fully open position.\u003c\/p\u003e\n\u003cp\u003eIf door will not run in closed direction, check for these or see chart below:\u003cbr\u003e• Misalignment of Safe-T-Beam® System (Red LED on source unit will be blinking).\u003cbr\u003e• Obstruction in path of beam.\u003cbr\u003e• Pinched or broken wire.\u003cbr\u003e• Loose wiring connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTroubleshooting Guide \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGenie Safe-T-Beam System Self Diagnostic Troubleshooting \u003c\/p\u003e\n\u003ctable style=\"width: 536px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003eSource (RED LED) \u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eSource (Green LED)\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003ePossible Problem \u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003eSolution \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003eNormal Operation \u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003eNone Required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003eOFF\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eOFF\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e\n\u003cp\u003e•Powerhead not powered \u003c\/p\u003e\n\u003cp\u003e•Wiring from Powerhead bad\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e\n\u003cp\u003e•Check breakers, fuses, plugs\u003c\/p\u003e\n\u003cp\u003e•Check wiring for obvoious shorts \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003eOFF\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e\n\u003cp\u003e•Wiring to source missing or bad\u003c\/p\u003e\n\u003cp\u003e•Power has been interrupted\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e•Check Wiring                                  •Remove power and reapply \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003e2 Blinks, Pause (Repeat)\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e\n\u003cp\u003e•Beam not aligned                   \u003c\/p\u003e\n\u003cp\u003e•Beam obstructed                   •Sensor defective \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e\n\u003cp\u003e•Check Source, sensor alignment\u003c\/p\u003e\n\u003cp\u003e•Check for obstruction          \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003e2 Blinks, Pause (Repeat)\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eOFF\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e\n\u003cp\u003e•Wire to sensor missing or bad\u003c\/p\u003e\n\u003cp\u003e•Sensor defective\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e•Check Wiring                             \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003e3 Blinks, Pause (Repeat)\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e•Sensor receiving interference\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e•Find source of interference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003e3 Blinks, Pause (Repeat)\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e\n\u003cp\u003e•Source not sending pulses\u003c\/p\u003e\n\u003cp\u003e•Source defective \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e•Contact Customer service \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIf you still have a problem, contact Customer Service at 1-800-35-GENIE.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_warning_medium.png?v=1559220809\" alt=\"Safe-T-Beam Warning \"\u003e\u003c\/p\u003e\n\u003cp\u003eORDERING INFO:\u003cbr\u003eTo order wire use the following part numbers:\u003c\/p\u003e\n\u003cp\u003eSafe-T-Beam wiring- part number \u003ca href=\"https:\/\/store.geniecompany.com\/collections\/wire-wire-clips\/products\/bell-wire\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e35265A.S and 35265B.S\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/store.geniecompany.com\/collections\/wire-wire-clips\/products\/bell-wire\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_wire_ordering_medium.png?v=1559220848\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDiagnostic Troubleshooting\u003c\/h5\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/stbdiagnostic2.jpg?6638189643415955466\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"Genie Safe-T-Beam System Self Diagnostic troubleshooting Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/stbdiagnostic2_large.jpg?v=1531249174\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSafe-T-Beam technology uses a continuous infrared \u003c\/span\u003e\u003cem class=\"rn_Highlight\"\u003ebeam\u003c\/em\u003e\u003cspan\u003e that projects across the interior of the garage door opening to a receiver at all times. In order for your garage door to operate, the \u003c\/span\u003e\u003cem class=\"rn_Highlight\"\u003ebeam\u003c\/em\u003e\u003cspan\u003e must be located at least five inches, but no more than six inches, from the floor, and it should be aligned so that the sensors “see” each other. During closing, if the \u003c\/span\u003e\u003cem class=\"rn_Highlight\"\u003ebeam\u003c\/em\u003e\u003cspan\u003e is interrupted by a person, animal or object, Safe-T-Beam automatically raises the garage door to protect whatever is in its path. Please note that the garage door opener will not close the door unless Safe-T-Beam® is installed and working properly.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- \/TABS --\u003e","published_at":"2017-04-26T16:21:53-04:00","created_at":"2017-04-03T15:51:25-04:00","vendor":"The Genie Company","type":"Sensors","tags":["Safety Beams"],"price":4199,"price_min":4199,"price_max":4199,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":36157483907,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"37220R","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Safe-T-Beam® Sensors","public_title":null,"options":["Default Title"],"price":4199,"weight":227,"compare_at_price":null,"inventory_quantity":998,"inventory_management":"shopify","inventory_policy":"continue","barcode":"050049017514"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/products\/37334R-04.jpg?v=1558531778","\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/products\/Untitled_design.png?v=1558531778","\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/products\/Genie_GSTB-R.gif?v=1558531778","\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/products\/beams_with_bike.jpg?v=1558531778","\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/products\/Safety-Beams_84e8e48d-62c1-4a1a-8c8e-c2b2f424ccde.jpg?v=1558531778"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/products\/37334R-04.jpg?v=1558531778","options":["Title"],"content":"\u003cp\u003eGenies Safe-T-Beam system is designed to ensure maximum safety for your garage door opener operation. Using an invisible infrared beam across the opening of the door, the Genie garage door sensor detects any object passing through the LED beam of light and automatically reverses the closing garage door, keeping children and pets safe.\u003c\/p\u003e\n\u003cp\u003eIf your Safe-T-Beam system has been damaged, a replacement kit is essential to continue safe operation of your garage door opener. This kit is compatible with Genie-only garage door openers manufactured since 1993 that use required safety beams. \u003c\/p\u003e\n\u003cp\u003eOnce installed, your replacement Safe-T-Beams are self-diagnostic and will alert you in the event of any malfunction. Don’t leave safety up to chance – replace your safety beams with this kit today.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReplacement Kit. Replaces broken or faulty safety beams in your Genie garage door opener’s Safe-T-Beam system.\u003c\/li\u003e\n\u003cli\u003eWorks with Many Genie Openers. Compatible with Genie (only) garage door openers manufactured since 1993 that utilize required safety beams.\u003c\/li\u003e\n\u003cli\u003eKeeps Family and Pets Safe. Places an invisible infrared beam across the door opening and reverses door automatically if an object passes through the LED beam of light.\u003c\/li\u003e\n\u003cli\u003eSelf-Diagnostic. Alerts you of any malfunction in installation or operation, as an additional safety measure.\u003c\/li\u003e\n\u003cli\u003eEasy Installation. Replacement kit is easy to install, with mounting brackets and hardware included \u003cspan\u003e(does not include bell wire).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eEquivalent to Genie part numbers 37334R and 37220R\u003c\/li\u003e\n\u003cli\u003eOften Referred to as garage door opener-  photo eyes, electric eyes, safety eyes, and safety sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e  \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003ca href=\"https:\/\/store.geniecompany.com\/pages\/proposition-65\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/trianglewarning_icon.jpg?v=1529498861\" alt=\"\" width=\"19\" height=\"19\"\u003e California\u003cspan\u003e Residents: \u003c\/span\u003eProposition 65 WARNING\u003c\/a\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c!-- TABS --\u003e\n\u003ch5\u003eReviews\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eInstallation Instructions\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/safetbeam.pdf?7882351353251902900\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/PDF_ICON_icon.png?v=1533737947\" alt=\"\"\u003e PDF Installation instructions for installing the Safe-T-Beams\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstalling the 37220R Replacement Safe-T-Beam System\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. IMPORTANT INFORMATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eWARNING\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eMoving Door can cause serious injury or death.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Wall control must be mounted in sight of garage door, at least 5 feet above floor and clear of moving parts.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Keep people clear of opening while door is moving.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Do Not allow children to play with remote or door opener.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eIf Safety Reverse does not work properly:\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Close door, then disconnect opener using manual release handle.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Do Not use remote or door opener.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Refer to Door and Door Opener Owner’s Manuals before attempting any repairs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eElectrical Shock can cause serious injury or death.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Power cord must be unplugged before attaching any wires.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Be sure wire ends do not touch each other or other terminals.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003eIf you have questions or if you need a manual, contact the distributor or manufacturer of the opener.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. MOUNTING SOURCE \u0026amp; SENSOR\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLocations of existing units can be reused if that is desired. Safe-T-Beam® System (STB) Source and Sensor do not have to be mounted on garage door frame. They can be placed anywhere along garage door wall that is convenient for mounting, provided the location meets the following requirements:\u003cbr\u003e1) They must be placed across the door opening,\u003cbr\u003e2) at the proper height,\u003cbr\u003e3) with a clear line of sight between them. (Max. Range is 30 feet).\u003cbr\u003e(They may be mounted on the floor, only as a last resort, if there is\u003cbr\u003eno other option. Not recommended.)\u003c\/p\u003e\n\u003cp\u003e1. To ease mounting, source and sensor units can be detached from the bracket by pulling them apart. After mounting brackets, slide units back onto brackets.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_Step_1_medium.png?v=1559219958\" alt=\"Installing Genie Safe-T-Beams replacements instructions Step 1 \"\u003e\u003c\/p\u003e\n\u003cp\u003e2. Ensure there will be an unobstructed path between source and sensor. Sensor should be mounted on the side of the garage door opening that receives the least direct sunlight.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_Step_2_medium.png?v=1559220038\" alt=\"Step 2 Replacing the Genie garage door opener Safe-T-Beam system\"\u003e\u003c\/p\u003e\n\u003cp\u003e3. Once the location is established, measure the height of bracket as shown. Hold the bracket in place and mark hole locations. 1\/8\" pilot holes are recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_Step_3_medium.png?v=1559220101\" alt=\"Installation of Safe-T-Beams for Genie garage door openers Height instructions\"\u003e\u003c\/p\u003e\n\u003cp\u003e*No height adjustment is needed for units mounted on floor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. WIRE RUN\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReuse of existing wiring is easiest and recommended unless it is broken, cut, frayed or there is a problem. If you can reuse existing wiring — SKIP FORWARD TO STEP 4. If new wiring must be installed, the path shown below is recommended.\u003c\/p\u003e\n\u003cp\u003e1. Route two (2) lengths of two (2) conductor wire (See above) from opener, along top of rail.\u003cbr\u003eFasten wire to rail.\u003cbr\u003e— Evenly space fasteners along rail.\u003cbr\u003eFasten to header and wall (preferably with insulated staples). Allow for some slack at the source and sensor units and cut off any excess wire.\u003cbr\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_Wire_Run_medium.png?v=1559220300\" alt=\"Genie replacement Safe-T-Beams installing the wiring \"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eCAUTION: When using insulated staples, be aware that staples which are too tight can cut or pinch wires. Cut or pinched wires can cause the Safe-T-Beam® System to stop working. When using insulated staples, make sure you fasten them only as tightly as needed to hold the wire snugly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e2. At source and sensor, route wires through bracket as shown and attach wires at terminals. Either wire to either terminal (non-polar).\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_No_Polarity_medium.png?v=1559220387\" alt=\"Genie 37220R Safe-T-Beam replacement wiring \"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e3. If installing new wiring:\u003cbr\u003eAt opener, twist striped wires together. Twist plain wires together. Feed down through control wire tube “chimney” at top of opener.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_wire_tube_medium.png?v=1559220529\" alt=\"Genie garage door opener power head Wire tube for Safe-T-Beam wiring \"\u003e\u003c\/p\u003e\n\u003cp\u003e4. Attach to terminals #1 and #2 (again either wire). Bundle excess wire and tape to top of power head.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_terminals_medium.png?v=1559220587\" alt=\"Genie replacement Safe-T-Beam system wiring to the terminals \"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. SAFE-T-BEAM® SYSTEM TEST\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSafe-T-Beam® System must be installed and working properly in order for door opener to function.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eCAUTION: During testing of the Safe-T-Beam® System, be sure to stay clear of the door and any moving parts. It is preferable to use a long-handled object to interrupt the beam during tests.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e1. Start door moving in close direction.\u003c\/p\u003e\n\u003cp\u003e2. Pass an object through the path of the Safe-T-Beam® System in order to interrupt beam.\u003cbr\u003e— Door should stop and reverse direction to fully open position.\u003c\/p\u003e\n\u003cp\u003eIf door will not run in closed direction, check for these or see chart below:\u003cbr\u003e• Misalignment of Safe-T-Beam® System (Red LED on source unit will be blinking).\u003cbr\u003e• Obstruction in path of beam.\u003cbr\u003e• Pinched or broken wire.\u003cbr\u003e• Loose wiring connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTroubleshooting Guide \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGenie Safe-T-Beam System Self Diagnostic Troubleshooting \u003c\/p\u003e\n\u003ctable style=\"width: 536px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003eSource (RED LED) \u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eSource (Green LED)\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003ePossible Problem \u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003eSolution \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003eNormal Operation \u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003eNone Required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003eOFF\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eOFF\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e\n\u003cp\u003e•Powerhead not powered \u003c\/p\u003e\n\u003cp\u003e•Wiring from Powerhead bad\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e\n\u003cp\u003e•Check breakers, fuses, plugs\u003c\/p\u003e\n\u003cp\u003e•Check wiring for obvoious shorts \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003eOFF\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e\n\u003cp\u003e•Wiring to source missing or bad\u003c\/p\u003e\n\u003cp\u003e•Power has been interrupted\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e•Check Wiring                                  •Remove power and reapply \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003e2 Blinks, Pause (Repeat)\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e\n\u003cp\u003e•Beam not aligned                   \u003c\/p\u003e\n\u003cp\u003e•Beam obstructed                   •Sensor defective \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e\n\u003cp\u003e•Check Source, sensor alignment\u003c\/p\u003e\n\u003cp\u003e•Check for obstruction          \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003e2 Blinks, Pause (Repeat)\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eOFF\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e\n\u003cp\u003e•Wire to sensor missing or bad\u003c\/p\u003e\n\u003cp\u003e•Sensor defective\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e•Check Wiring                             \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003e3 Blinks, Pause (Repeat)\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e•Sensor receiving interference\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e•Find source of interference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 88px;\"\u003e3 Blinks, Pause (Repeat)\u003c\/td\u003e\n\u003ctd style=\"width: 73px;\"\u003eON\u003c\/td\u003e\n\u003ctd style=\"width: 224.83px;\"\u003e\n\u003cp\u003e•Source not sending pulses\u003c\/p\u003e\n\u003cp\u003e•Source defective \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 134.17px;\"\u003e•Contact Customer service \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIf you still have a problem, contact Customer Service at 1-800-35-GENIE.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_warning_medium.png?v=1559220809\" alt=\"Safe-T-Beam Warning \"\u003e\u003c\/p\u003e\n\u003cp\u003eORDERING INFO:\u003cbr\u003eTo order wire use the following part numbers:\u003c\/p\u003e\n\u003cp\u003eSafe-T-Beam wiring- part number \u003ca href=\"https:\/\/store.geniecompany.com\/collections\/wire-wire-clips\/products\/bell-wire\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e35265A.S and 35265B.S\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/store.geniecompany.com\/collections\/wire-wire-clips\/products\/bell-wire\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37220R_Genie_Safe-T-Beam_Replacement_Instructions_wire_ordering_medium.png?v=1559220848\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDiagnostic Troubleshooting\u003c\/h5\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/stbdiagnostic2.jpg?6638189643415955466\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"Genie Safe-T-Beam System Self Diagnostic troubleshooting Guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/stbdiagnostic2_large.jpg?v=1531249174\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSafe-T-Beam technology uses a continuous infrared \u003c\/span\u003e\u003cem class=\"rn_Highlight\"\u003ebeam\u003c\/em\u003e\u003cspan\u003e that projects across the interior of the garage door opening to a receiver at all times. In order for your garage door to operate, the \u003c\/span\u003e\u003cem class=\"rn_Highlight\"\u003ebeam\u003c\/em\u003e\u003cspan\u003e must be located at least five inches, but no more than six inches, from the floor, and it should be aligned so that the sensors “see” each other. During closing, if the \u003c\/span\u003e\u003cem class=\"rn_Highlight\"\u003ebeam\u003c\/em\u003e\u003cspan\u003e is interrupted by a person, animal or object, Safe-T-Beam automatically raises the garage door to protect whatever is in its path. Please note that the garage door opener will not close the door unless Safe-T-Beam® is installed and working properly.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- \/TABS --\u003e"}

Safe-T-Beam® Sensors

Product Description
$41.99
Maximum quantity available reached.

Genies Safe-T-Beam system is designed to ensure maximum safety for your garage door opener operation. Using an invisible infrared beam across the opening of the door, the Genie garage door sensor detects any object passing through the LED beam of light and automatically reverses the closing garage door, keeping children and pets safe.

If your Safe-T-Beam system has been damaged, a replacement kit is essential to continue safe operation of your garage door opener. This kit is compatible with Genie-only garage door openers manufactured since 1993 that use required safety beams. 

Once installed, your replacement Safe-T-Beams are self-diagnostic and will alert you in the event of any malfunction. Don’t leave safety up to chance – replace your safety beams with this kit today.

  • Replacement Kit. Replaces broken or faulty safety beams in your Genie garage door opener’s Safe-T-Beam system.
  • Works with Many Genie Openers. Compatible with Genie (only) garage door openers manufactured since 1993 that utilize required safety beams.
  • Keeps Family and Pets Safe. Places an invisible infrared beam across the door opening and reverses door automatically if an object passes through the LED beam of light.
  • Self-Diagnostic. Alerts you of any malfunction in installation or operation, as an additional safety measure.
  • Easy Installation. Replacement kit is easy to install, with mounting brackets and hardware included (does not include bell wire).
  • Equivalent to Genie part numbers 37334R and 37220R
  • Often Referred to as garage door opener-  photo eyes, electric eyes, safety eyes, and safety sensors

  

 California Residents: Proposition 65 WARNING

Sku: 37220R

 PDF Installation instructions for installing the Safe-T-Beams

Installing the 37220R Replacement Safe-T-Beam System

1. IMPORTANT INFORMATION

WARNING

Moving Door can cause serious injury or death.

• Wall control must be mounted in sight of garage door, at least 5 feet above floor and clear of moving parts.
• Keep people clear of opening while door is moving.
• Do Not allow children to play with remote or door opener.

If Safety Reverse does not work properly:
• Close door, then disconnect opener using manual release handle.
• Do Not use remote or door opener.
• Refer to Door and Door Opener Owner’s Manuals before attempting any repairs.

Electrical Shock can cause serious injury or death.
• Power cord must be unplugged before attaching any wires.
• Be sure wire ends do not touch each other or other terminals.
If you have questions or if you need a manual, contact the distributor or manufacturer of the opener.

2. MOUNTING SOURCE & SENSOR

Locations of existing units can be reused if that is desired. Safe-T-Beam® System (STB) Source and Sensor do not have to be mounted on garage door frame. They can be placed anywhere along garage door wall that is convenient for mounting, provided the location meets the following requirements:
1) They must be placed across the door opening,
2) at the proper height,
3) with a clear line of sight between them. (Max. Range is 30 feet).
(They may be mounted on the floor, only as a last resort, if there is
no other option. Not recommended.)

1. To ease mounting, source and sensor units can be detached from the bracket by pulling them apart. After mounting brackets, slide units back onto brackets.

Installing Genie Safe-T-Beams replacements instructions Step 1

2. Ensure there will be an unobstructed path between source and sensor. Sensor should be mounted on the side of the garage door opening that receives the least direct sunlight.

Step 2 Replacing the Genie garage door opener Safe-T-Beam system

3. Once the location is established, measure the height of bracket as shown. Hold the bracket in place and mark hole locations. 1/8" pilot holes are recommended.

Installation of Safe-T-Beams for Genie garage door openers Height instructions

*No height adjustment is needed for units mounted on floor.

3. WIRE RUN

Reuse of existing wiring is easiest and recommended unless it is broken, cut, frayed or there is a problem. If you can reuse existing wiring — SKIP FORWARD TO STEP 4. If new wiring must be installed, the path shown below is recommended.

1. Route two (2) lengths of two (2) conductor wire (See above) from opener, along top of rail.
Fasten wire to rail.
— Evenly space fasteners along rail.
Fasten to header and wall (preferably with insulated staples). Allow for some slack at the source and sensor units and cut off any excess wire.
Genie replacement Safe-T-Beams installing the wiring

 

CAUTION: When using insulated staples, be aware that staples which are too tight can cut or pinch wires. Cut or pinched wires can cause the Safe-T-Beam® System to stop working. When using insulated staples, make sure you fasten them only as tightly as needed to hold the wire snugly.

2. At source and sensor, route wires through bracket as shown and attach wires at terminals. Either wire to either terminal (non-polar).

Genie 37220R Safe-T-Beam replacement wiring

 

3. If installing new wiring:
At opener, twist striped wires together. Twist plain wires together. Feed down through control wire tube “chimney” at top of opener.

Genie garage door opener power head Wire tube for Safe-T-Beam wiring

4. Attach to terminals #1 and #2 (again either wire). Bundle excess wire and tape to top of power head.

Genie replacement Safe-T-Beam system wiring to the terminals

4. SAFE-T-BEAM® SYSTEM TEST

Safe-T-Beam® System must be installed and working properly in order for door opener to function.

CAUTION: During testing of the Safe-T-Beam® System, be sure to stay clear of the door and any moving parts. It is preferable to use a long-handled object to interrupt the beam during tests.

1. Start door moving in close direction.

2. Pass an object through the path of the Safe-T-Beam® System in order to interrupt beam.
— Door should stop and reverse direction to fully open position.

If door will not run in closed direction, check for these or see chart below:
• Misalignment of Safe-T-Beam® System (Red LED on source unit will be blinking).
• Obstruction in path of beam.
• Pinched or broken wire.
• Loose wiring connection.

Troubleshooting Guide 

Genie Safe-T-Beam System Self Diagnostic Troubleshooting 

Source (RED LED)  Source (Green LED) Possible Problem  Solution 
ON ON Normal Operation  None Required
OFF OFF

•Powerhead not powered 

•Wiring from Powerhead bad

•Check breakers, fuses, plugs

•Check wiring for obvoious shorts 

OFF ON

•Wiring to source missing or bad

•Power has been interrupted

•Check Wiring                                  •Remove power and reapply 
2 Blinks, Pause (Repeat) ON

•Beam not aligned                   

•Beam obstructed                   •Sensor defective 

•Check Source, sensor alignment

•Check for obstruction          

2 Blinks, Pause (Repeat) OFF

•Wire to sensor missing or bad

•Sensor defective

•Check Wiring                             
3 Blinks, Pause (Repeat) ON •Sensor receiving interference •Find source of interference
3 Blinks, Pause (Repeat) ON

•Source not sending pulses

•Source defective 

•Contact Customer service 

If you still have a problem, contact Customer Service at 1-800-35-GENIE.

Safe-T-Beam Warning

ORDERING INFO:
To order wire use the following part numbers:

Safe-T-Beam wiring- part number 35265A.S and 35265B.S

 

Genie Safe-T-Beam System Self Diagnostic troubleshooting Guide

 

Safe-T-Beam technology uses a continuous infrared beam that projects across the interior of the garage door opening to a receiver at all times. In order for your garage door to operate, the beam must be located at least five inches, but no more than six inches, from the floor, and it should be aligned so that the sensors “see” each other. During closing, if the beam is interrupted by a person, animal or object, Safe-T-Beam automatically raises the garage door to protect whatever is in its path. Please note that the garage door opener will not close the door unless Safe-T-Beam® is installed and working properly.

Questions & Answers

Ask a Question
  • Just want to confirm these are compatible with model H4000-07/M?

    Yes, these Safe-T-Beam sensors will work with the H4000-07/M model. 

  • Are these compatible with Model 1024 Genie Pro? Thanks.

    Yes, the Genie Sate-T-Beam Sensors (37220R) will work with the 1024 model Genie.

  • Confirming this is compatible with Silentmax 1000, model 3042?

    Yes they are. 

  • Will they work with Pro Max PMX500IC/B. Receiver Model: ACSR1?

    Yes, these safety beams will work with the PMX500IC/B models. 

  • Are they compatible with the Genie Excellerator Opener

    Yes these will work with The Genie Excelerator models. 

  • Are these compatible with Model #ISD995 (Genie Excelerator)?

    Yes they are. 

  • I, as well, would like to confirm this will work with my H6000-07M. Thank you...

    Yes they will! 

  • Will they work with the powerlift 900

    Yes they will!

  • is this compatible with model isl950/a

    Yes they are! 

  • Are these compatible with Model #2024?

    Yes, they are! 

  • Will they work with model #2020L

    Yes! The Safe-T-Beam Sensors will work with the Genie model 2020L garage door opener. 

  • Will these work with the IS/550 opener

    Yes, these will work with the IS550 garage door opener. 

  • will these Safe-T-Beam sensors work on H4000 A

    Yes, they will! 

  • Will these work for Relia G 650?

    Yes, they will! 

  • Will this work for a 1/2 H.P. Model PCG650?

    Yes, they will. 

  • Will these sensors work with Model #H600A?

    Yes, they will! 

  • Are these sensors compatible with Overhead Door Model: 696CD/B?

    Yes, they are! 

  • Are these sensors compatible with the H8000-07/M opener?

    Yes, they are! 

  • Will these work for Residential Door 1/2 H.P. Model IMS 1000/A; Receiver model ACSR3G?

    Yes, they will. 

  • the red led flash twice and repeat on STB sensor what is the problem

    This usually means they are misaligned. You will want to make sure the green light is on and make sure they did not get bumped. For assistance call 1.800.354.3643. 

  • Will sensors be compatible with genie 900 power lift

    Yes, they are! 

  • Will these work on intelli g 1200 And can I order just two green ones

    Yes, they will work. They come with one red and one green. 

  • Will sensor PN 37334R work with Genie Model GXL9500?

    Yes, it will. 

  • Will these work with a Genie model IS550/A?

    Yes, they will! 

  • will these sensors work on model 2060l-07 model

    Yes, they will! 

  • Just want to confirm these are compatible with model H4000-A2?

    Yes, they are! 

  • will these sensors work on a chamberlain unit

    No, they will not. 

  • Is this one sensor, or is it a set of two sensors?

    This comes with two, the one with the red light and the one with the green light. 

  • will these Safe-T-Beam sensors work on GPS1200IC

    Yes, they will!

  • Do these work with Model #isd990

    Yes, they do.

  • will this unit work with GPS-1C SERIES.PMX-1C B SERIES?

    Yes, these Safe-T-Beams will work with the GPS-IC and PMXIC/B series garage door openers.

  • Are these sensors compatible with Genie Bluemax?

    They are as long as you have the plugs for the safe-t-beams that originally came with the BlueMax opener.

  • will these sensors work with th modelIs550/A

    Yes, they will!

  • Are these compatible with Model H6000A?

    Yes, they are.

  • We have a G5000 and need new beams will these work as replacements

    Yes, these will work as long as you have the plugs that were on the old safe-t-beams.

  • I would like to order Genies Safe-T-Beam sensor to replace my faulty sensor . is 1 unit in the quantity is 1 pair of sensors or just 1 sensor?

    This is a pair, so you will get 2 sensors, one with the red light and one with the green.

  • Can the safe-t-bean work with a Lift Master Formula 1?

    No, these will not work with Liftmaster brand garage door openers.

  • I have a couple of old g5000 1/2 hp screw drive (red case) openers. They work fine, but the wires got broken off right at one of the sensors. Too closed to repair. What do you suggest?

    You can use the new Safe-T-Beam sensors to replace the old ones. You will just use the old wiring and splice where they connected to the old. For more information, please contact Genie customer service at 1-800-354-3643.

  • Just want to confirm these are compatible with model ACSR3G?

    Yes, they are.

  • since the wiring has been massed up, should this kit be connected to terminal/connector 1 and 2? my genie pro has 4 connectors/terminals numbered as 1, 2, 3, and 4 thanks

    This will depend on which model garage door opener you have. Most of the older models, the Safe-T-Beams connected to terminals 3 and 4, newer models, to 1 and 2. You can view your owners manual here for more details, or you can contact our customer service at 1-800-354-3643 for assistance.

  • Will the safe-t-beam work on model H6000A

    Yes, they will.

  • i have a H6000A opener and the red safe T beam is blinking 4 times and the green one is not on. what could be the problem? i've cleaned the lenses and checked the wires.

    If the green one is not on, that will cause the other one with the red light to blink. On the green one, it could be either that the safe-t-beam is bad, or that the wire to the green one is broken or bad. The best way to check the wiring would be to take the red one off the wires it is attached to, and hook the green one up to those wires. If it lights up, then the wire to the green one is not working or broken, if it does not light up, then the safe-t-beams will need to be replaced.

  • Will this work with my gcg350 l garage door opener?

    Yes, these Safe-T-Beams will work with the GCG350.

  • I have a Genie Bluemax CM 7500-S. There are two wires running from the opener to the source unit, and two wires running from the source to the receiver/sensor. The plug ends on the receiver are broken. The wiring diagram in the on-line instruction sheet shows two wires running from the opener to the source and two wires running from the opener to the sensor. Can I install these replacement units and how do I rewire them?

    Yes, you can use these replacement Safe-T-Beams with the CM7500-S model garage door opener. Please contact Genie customer service at 1-800-354-3643 for assistance with the wiring.

  • it work with 1/2 genie hp screw drive

    This depends on the model. Please contact Genie customer service at 1-800-354-3643 for assistance with compatibility.

  • Should the green and red lights flash or just green on the sensors when new ones are installed.

    You should have one solid red light, and one solid green light on the Safe-t-Beams. If the red one is flashing that indicates a problem, obstruction, or that they are misaligned.

  • Will these work on a 1/3 horsepower model pcg450?

    Yes, they will!

  • In the instructions, it says that the sensor unit pulls apart from the bracket, but I have tried and the unit does not separate. I have pulled fairly hard, but I don't want to break the unit. There doesn't seem to be a catch release nor does it mention one in the instructions.

    They do separate, but it does require quite a large amount of force.  We recommend using rubber gloves on both hands and pulling with ample force.  It does kind of feel like it will break but should not break when you are separating. 

  • Hello I have a intellercode model 5550/a and the safety receiver blinks red always opens but when you close it. It starts to close but goes right back to open. Can't find the original style safety sensor. May that be my problem. Thanks for your help Ben

    You can use the Safe-T-Beam diagnostic blinks to help find what the issue is. (found in the details on this page)- or you can contact our customer service at 1-800-354-3643 for troubleshooting assistance.

  • Will these sensors work with the Genie Chainmax 1000?

    Yes! These Safe-T-Beam sensors will work with the Genie ChainMax 1000 model garage door opener.

  • Genie Sate-T-Beam Sensors (37220R): What kind of maximum distance (range) do these sensors have? 30 or so feet ?

    The Safe-T-Beams are only guaranteed at 25 feet, however, they may work greater distances than this.