{"id":10832259715,"title":"Circuit Board \/ Series II Wall Console Bundle 38875R4.S","handle":"circuit-board-and-series-ii-wall-console-4022-4042-4024","description":"\u003cp\u003e\u003cspan\u003eThis Configured circuit board with series II wall console bundle is for Genie chain or belt drive models listed below. \u003c\/span\u003e\u003cspan\u003eUse this replacement circuit board and wall console bundle to get your garage door opener back up and running quickly if you have determined your circuit board needs to be replaced.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with models 4022, 4042, 4024 (IntelliG 1200, SilentMax 1200) \u003c\/li\u003e\n\u003cli\u003eGenuine Genie replacement parts\u003c\/li\u003e\n\u003cli\u003eRequires re-programming with the new board \u003c\/li\u003e\n\u003cli\u003eCircuit board and series II wall console included - Plus DIY detailed replacement instructions \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- TABS --\u003e\n\u003ch5\u003eReviews\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eInstallation Instructions\u003c\/h5\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/38875R3.S_Replacement_Board.pdf?4125\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/PDF_ICON_icon.png?v=1533737947\"\u003e PDF Instructions for replacing the 38875R4.S circuit board \u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/Programming_Travel_Limits_when_replacing_the_circuit_board.pdf?4125\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/PDF_ICON_icon.png?v=1533737947\"\u003e PDF Instructions for resetting the opener travel Limits after replacing the 38875R4.S circuit board \u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/www.geniecompany.com\/data\/products\/accessories\/wall-console-series-II_ENG-FRE_02-01-2015.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/PDF_ICON_icon.png?v=1533737947\"\u003e PDF Installation Instructions for replacing the Series II wall console\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e38875R4.S DC Control Board Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese instructions are written assuming that you will have ample room around Opener to perform this repair. Some rare instances will require removal of the unit from its mounting hardware and repair made on a bench or floor. Refer to your\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.geniecompany.com\/data\/products\/genie_owners-manual_eng.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eOwner’s Manual\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003efor proper assembly and carefully read and understand all warnings and cautions pertaining to your unit.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eWARNING!\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eBE SURE ELECTRICAL POWER HAS BEEN DISCONNECTED FROM THE INPUT POWER LINES PRIOR TO REMOVING THE MOTOR COVER.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eWARNING!\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eANY AND ALL REPAIRS MADE TO THIS UNIT MUST BE PERFORMED WITH THE DOOR DISCONNECTED FROM THE OPENER AND IN THE CLOSED POSITION.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e1. Pull emergency release cord on the carriage to disengage opener to close the door if necessary. (If unable to lower door using an opener, use extreme caution manually closing the door. Before pulling the emergency release cord, make certain people and objects are clear of the door opening.)\u003c\/p\u003e\n\u003cp\u003e2. Unplug the opener power cord from power receptacle.\u003c\/p\u003e\n\u003cp\u003e3. Open lens cover by pressing middle tab inward and remove light bulbs. FIG. 1.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg alt=\"Circuit Board Replacement 38875R4.S figure 1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/38875R3.S_Replacement_Circuit_Board_Fig.1_large.png?v=1558617185\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003cp\u003e4. Remove wall control and Safe-T-Beam wires from the terminal block located on side of opener FIG. 1. Use a small common screwdriver to press in on orange tabs while gently pulling wires from the block. Mark wires to help facilitate replacement.\u003c\/p\u003e\n\u003cp\u003e5. Unplug any optional accessories such as the battery backup and\/or networking adapter.\u003c\/p\u003e\n\u003cp\u003e6. Remove two 5\/16” screws securing powerhead cover to chassis. FIG. 2.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg alt=\"Genie Circuit board replacement figure 3, part 38875R4.S\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/38875R3.S_Replacement_Circuit_Board_Fig.2_large.png?v=1558617231\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003cp\u003e7. Allow the motor cover to swing down to access control board and wire harnesses.\u003c\/p\u003e\n\u003cp\u003e8. Unplug the following harnesses from the control board. FIG. 4.\u003c\/p\u003e\n\u003cp\u003e• Light harness\u003c\/p\u003e\n\u003cp\u003e• Motor harness\u003c\/p\u003e\n\u003cp\u003e• Opto harness (see step 12-13)\u003c\/p\u003e\n\u003cp\u003e• AC IN harness\u003c\/p\u003e\n\u003cp\u003e• Motion Detector harness (if equipped)\u003c\/p\u003e\n\u003cp\u003e• Green ground wire to chassis (if equipped).\u003c\/p\u003e\n\u003cp\u003eREMOVE AND DISCARD.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg alt=\"Genie 38875R4.S Circuit board replacement figure 3\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/38875R3.S_Replacement_Circuit_Board_Fig.3_large.png?v=1558617270\" style=\"float: none;\"\u003e \u003cimg alt=\"Genie 38875R4.S Circuit board replacement figure 4\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/38875R3.S_Replacement_Circuit_Board_Fig.4_large.png?v=1558617299\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003cp\u003e9. Powerhead cover can now be removed from opener chassis for repair. Special care should be taken to prevent damage to the motion detector bulb \u003cspan\u003e(If equipped) \u003c\/span\u003elocated on the bottom of the motor cover. \u003c\/p\u003e\n\u003cp\u003e10. Remove control board mounting screws and the old control board. FIG 3.\u003c\/p\u003e\n\u003cp\u003e11. Feed antenna wire through the hole in the cover. Mount the 38875R4.S replacement control board to cover and secure with screws removed in step 10.\u003c\/p\u003e\n\u003cp\u003e--- SEE BELOW FOR MOTOR TYPES ---\u003c\/p\u003e\n\u003cp\u003e12. If your motor compares to MOTOR TYPE 1. Remove existing harness from the motor and plug pre-installed OPTO SENSOR harness from new control board directly into the motor.\u003c\/p\u003e\n\u003cp\u003e13. If your motor compares to MOTOR TYPE 2. Remove pre-installed OPTO SENSOR harness from the control board and plug existing OPTO harness from the motor into DUAL ENCODER OPTO SENSOR plug on replacement control board. (Or use new harness packed with control board).\u003c\/p\u003e\n\u003cp\u003e14. Hang powerhead cover to chassis to connect all other harnesses removed in step 8.\u003c\/p\u003e\n\u003cp\u003e15. Swing powerhead cover-up onto chassis and secure using screws removed in step 6.\u003c\/p\u003e\n\u003cp\u003e16. Install wall control and Safe-T-Beam wires. Install battery backup and\/or network harnesses if applicable.\u003c\/p\u003e\n\u003cp\u003e17. Install light bulbs and close lens cover.\u003c\/p\u003e\n\u003cp\u003e18. Reapply power to the opener.\u003c\/p\u003e\n\u003cp\u003e19. Limit controls, transmitters, and full function test will be required. Refer to the\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.geniecompany.com\/data\/products\/genie_owners-manual_eng.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eowner’s manual\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eand\/or assembly poster for detailed information  \u003c\/p\u003e\n\u003cp\u003e20. See below to replace the wall console \u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg alt=\"Genie motor type images for replacement circuit board 38875R4.S\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/38875R3.S_Replacement_Circuit_Board_Motor_Types_Figure_grande.png?v=1558617333\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSTALLING REPLACEMENT SERIES II WALL CONSOLE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• Disconnect power to the powerhead.\u003c\/p\u003e\n\u003cp\u003e• Remove existing wall console from the wall by removing mounting screws.• Remove wires from existing wall console.\u003c\/p\u003e\n\u003cp\u003e• Split and strip ends of the wire if it is needed (Fig. 2).\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg alt=\"replacing the Genie wall console \" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/wc_fig_2_medium.png?v=1548876120\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• \u003c\/strong\u003eFasten the wire to control board screws on the back of the wall console (Fig. 3):\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg alt=\"Genie wall console replacement instructions \" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/wc_fig_3_medium.png?v=1548876180\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg alt=\"wiring for replacing the Genie garage door opener wall console\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/wc_fig_7_large.png?v=1548876688\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003cp\u003e• Connect white wire between powerhead terminal #3 to wall console terminal “W.” (Fig 3 \u0026amp; 7).\u003c\/p\u003e\n\u003cp\u003e• Connect striped wire between powerhead terminal #4 to wall console terminal “B.” (Fig 3 \u0026amp; 7).\u003c\/p\u003e\n\u003cp\u003eNOTE: When existing wires have a color code different from above (FIG. 3), or none at all—make sure the wires are connected between terminals as directed above. When the wires are connected to the opposite terminals, the Sure-Lock® and Light feature may not function. The first indication of incorrect wiring is the backlight will be OFF.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• \u003c\/span\u003eMount wall console to wall using screws provided. Verify height at least 5 ft. above the floor (Fig. 4).\u003c\/p\u003e\n\u003cp\u003eReconnect power to the powerhead.\u003c\/p\u003e\n\u003cp\u003e• Check operation of each wall console button and feature (If the circuit board was replaced, and then the wall console, reset the limits on the garage door opener before checking the wall console features.) \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/wc_fig_4_medium.png?v=1548876302\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c!-- \/TABS --\u003e","published_at":"2017-09-01T13:25:36-04:00","created_at":"2017-09-01T13:27:37-04:00","vendor":"The Genie Company","type":"Service Parts","tags":["Circuit Board"],"price":14029,"price_min":14029,"price_max":14029,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":44260062787,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"38875R4.S","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Circuit Board \/ Series II Wall Console Bundle 38875R4.S","public_title":null,"options":["Default Title"],"price":14029,"weight":227,"compare_at_price":null,"inventory_quantity":999,"inventory_management":"shopify","inventory_policy":"continue","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/products\/38875R3.S-Board-F_ae6995c3-a7a9-43b1-a951-94ff87255c93.jpg?v=1555442487","\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/products\/38875R3.S-Board-T_b203980e-cd29-49dc-a522-da25cd5de192.jpg?v=1555442509"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/products\/38875R3.S-Board-F_ae6995c3-a7a9-43b1-a951-94ff87255c93.jpg?v=1555442487","options":["Title"],"content":"\u003cp\u003e\u003cspan\u003eThis Configured circuit board with series II wall console bundle is for Genie chain or belt drive models listed below. \u003c\/span\u003e\u003cspan\u003eUse this replacement circuit board and wall console bundle to get your garage door opener back up and running quickly if you have determined your circuit board needs to be replaced.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with models 4022, 4042, 4024 (IntelliG 1200, SilentMax 1200) \u003c\/li\u003e\n\u003cli\u003eGenuine Genie replacement parts\u003c\/li\u003e\n\u003cli\u003eRequires re-programming with the new board \u003c\/li\u003e\n\u003cli\u003eCircuit board and series II wall console included - Plus DIY detailed replacement instructions \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- TABS --\u003e\n\u003ch5\u003eReviews\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eInstallation Instructions\u003c\/h5\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/38875R3.S_Replacement_Board.pdf?4125\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/PDF_ICON_icon.png?v=1533737947\"\u003e PDF Instructions for replacing the 38875R4.S circuit board \u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/Programming_Travel_Limits_when_replacing_the_circuit_board.pdf?4125\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/PDF_ICON_icon.png?v=1533737947\"\u003e PDF Instructions for resetting the opener travel Limits after replacing the 38875R4.S circuit board \u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/www.geniecompany.com\/data\/products\/accessories\/wall-console-series-II_ENG-FRE_02-01-2015.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/PDF_ICON_icon.png?v=1533737947\"\u003e PDF Installation Instructions for replacing the Series II wall console\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e38875R4.S DC Control Board Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese instructions are written assuming that you will have ample room around Opener to perform this repair. Some rare instances will require removal of the unit from its mounting hardware and repair made on a bench or floor. Refer to your\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.geniecompany.com\/data\/products\/genie_owners-manual_eng.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eOwner’s Manual\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003efor proper assembly and carefully read and understand all warnings and cautions pertaining to your unit.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eWARNING!\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eBE SURE ELECTRICAL POWER HAS BEEN DISCONNECTED FROM THE INPUT POWER LINES PRIOR TO REMOVING THE MOTOR COVER.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eWARNING!\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eANY AND ALL REPAIRS MADE TO THIS UNIT MUST BE PERFORMED WITH THE DOOR DISCONNECTED FROM THE OPENER AND IN THE CLOSED POSITION.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e1. Pull emergency release cord on the carriage to disengage opener to close the door if necessary. (If unable to lower door using an opener, use extreme caution manually closing the door. Before pulling the emergency release cord, make certain people and objects are clear of the door opening.)\u003c\/p\u003e\n\u003cp\u003e2. Unplug the opener power cord from power receptacle.\u003c\/p\u003e\n\u003cp\u003e3. Open lens cover by pressing middle tab inward and remove light bulbs. FIG. 1.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg alt=\"Circuit Board Replacement 38875R4.S figure 1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/38875R3.S_Replacement_Circuit_Board_Fig.1_large.png?v=1558617185\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003cp\u003e4. Remove wall control and Safe-T-Beam wires from the terminal block located on side of opener FIG. 1. Use a small common screwdriver to press in on orange tabs while gently pulling wires from the block. Mark wires to help facilitate replacement.\u003c\/p\u003e\n\u003cp\u003e5. Unplug any optional accessories such as the battery backup and\/or networking adapter.\u003c\/p\u003e\n\u003cp\u003e6. Remove two 5\/16” screws securing powerhead cover to chassis. FIG. 2.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg alt=\"Genie Circuit board replacement figure 3, part 38875R4.S\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/38875R3.S_Replacement_Circuit_Board_Fig.2_large.png?v=1558617231\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003cp\u003e7. Allow the motor cover to swing down to access control board and wire harnesses.\u003c\/p\u003e\n\u003cp\u003e8. Unplug the following harnesses from the control board. FIG. 4.\u003c\/p\u003e\n\u003cp\u003e• Light harness\u003c\/p\u003e\n\u003cp\u003e• Motor harness\u003c\/p\u003e\n\u003cp\u003e• Opto harness (see step 12-13)\u003c\/p\u003e\n\u003cp\u003e• AC IN harness\u003c\/p\u003e\n\u003cp\u003e• Motion Detector harness (if equipped)\u003c\/p\u003e\n\u003cp\u003e• Green ground wire to chassis (if equipped).\u003c\/p\u003e\n\u003cp\u003eREMOVE AND DISCARD.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg alt=\"Genie 38875R4.S Circuit board replacement figure 3\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/38875R3.S_Replacement_Circuit_Board_Fig.3_large.png?v=1558617270\" style=\"float: none;\"\u003e \u003cimg alt=\"Genie 38875R4.S Circuit board replacement figure 4\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/38875R3.S_Replacement_Circuit_Board_Fig.4_large.png?v=1558617299\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003cp\u003e9. Powerhead cover can now be removed from opener chassis for repair. Special care should be taken to prevent damage to the motion detector bulb \u003cspan\u003e(If equipped) \u003c\/span\u003elocated on the bottom of the motor cover. \u003c\/p\u003e\n\u003cp\u003e10. Remove control board mounting screws and the old control board. FIG 3.\u003c\/p\u003e\n\u003cp\u003e11. Feed antenna wire through the hole in the cover. Mount the 38875R4.S replacement control board to cover and secure with screws removed in step 10.\u003c\/p\u003e\n\u003cp\u003e--- SEE BELOW FOR MOTOR TYPES ---\u003c\/p\u003e\n\u003cp\u003e12. If your motor compares to MOTOR TYPE 1. Remove existing harness from the motor and plug pre-installed OPTO SENSOR harness from new control board directly into the motor.\u003c\/p\u003e\n\u003cp\u003e13. If your motor compares to MOTOR TYPE 2. Remove pre-installed OPTO SENSOR harness from the control board and plug existing OPTO harness from the motor into DUAL ENCODER OPTO SENSOR plug on replacement control board. (Or use new harness packed with control board).\u003c\/p\u003e\n\u003cp\u003e14. Hang powerhead cover to chassis to connect all other harnesses removed in step 8.\u003c\/p\u003e\n\u003cp\u003e15. Swing powerhead cover-up onto chassis and secure using screws removed in step 6.\u003c\/p\u003e\n\u003cp\u003e16. Install wall control and Safe-T-Beam wires. Install battery backup and\/or network harnesses if applicable.\u003c\/p\u003e\n\u003cp\u003e17. Install light bulbs and close lens cover.\u003c\/p\u003e\n\u003cp\u003e18. Reapply power to the opener.\u003c\/p\u003e\n\u003cp\u003e19. Limit controls, transmitters, and full function test will be required. Refer to the\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.geniecompany.com\/data\/products\/genie_owners-manual_eng.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eowner’s manual\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eand\/or assembly poster for detailed information  \u003c\/p\u003e\n\u003cp\u003e20. See below to replace the wall console \u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg alt=\"Genie motor type images for replacement circuit board 38875R4.S\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/38875R3.S_Replacement_Circuit_Board_Motor_Types_Figure_grande.png?v=1558617333\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSTALLING REPLACEMENT SERIES II WALL CONSOLE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• Disconnect power to the powerhead.\u003c\/p\u003e\n\u003cp\u003e• Remove existing wall console from the wall by removing mounting screws.• Remove wires from existing wall console.\u003c\/p\u003e\n\u003cp\u003e• Split and strip ends of the wire if it is needed (Fig. 2).\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg alt=\"replacing the Genie wall console \" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/wc_fig_2_medium.png?v=1548876120\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• \u003c\/strong\u003eFasten the wire to control board screws on the back of the wall console (Fig. 3):\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg alt=\"Genie wall console replacement instructions \" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/wc_fig_3_medium.png?v=1548876180\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg alt=\"wiring for replacing the Genie garage door opener wall console\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/wc_fig_7_large.png?v=1548876688\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003cp\u003e• Connect white wire between powerhead terminal #3 to wall console terminal “W.” (Fig 3 \u0026amp; 7).\u003c\/p\u003e\n\u003cp\u003e• Connect striped wire between powerhead terminal #4 to wall console terminal “B.” (Fig 3 \u0026amp; 7).\u003c\/p\u003e\n\u003cp\u003eNOTE: When existing wires have a color code different from above (FIG. 3), or none at all—make sure the wires are connected between terminals as directed above. When the wires are connected to the opposite terminals, the Sure-Lock® and Light feature may not function. The first indication of incorrect wiring is the backlight will be OFF.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• \u003c\/span\u003eMount wall console to wall using screws provided. Verify height at least 5 ft. above the floor (Fig. 4).\u003c\/p\u003e\n\u003cp\u003eReconnect power to the powerhead.\u003c\/p\u003e\n\u003cp\u003e• Check operation of each wall console button and feature (If the circuit board was replaced, and then the wall console, reset the limits on the garage door opener before checking the wall console features.) \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/wc_fig_4_medium.png?v=1548876302\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c!-- \/TABS --\u003e"}
Genie replacement Circuit Board with Series II Wall Console Bundle 38875R4.S

Circuit Board / Series II Wall Console Bundle 38875R4.S

$140.29

This Configured circuit board with series II wall console bundle is for Genie chain or belt drive models listed below. Use this replacement circuit board and wall console bundle to get your garage door opener back up and running quickly if you have determined your circuit board needs to be replaced. Compatible with models 4022, 4042, 4024 (Inte...


More Info