Free Shipping On All U.S. Orders $14.99 +
{"id":10552692419,"title":"Control Board (6 Terminal Board) 36190S.S","handle":"control-board-6-terminal-board-ml","description":"\u003cp\u003eConfigured circuit board for Chain Glide openers that have 6 terminals strip (models that have magnetic limits). This 6 terminal control board will get your garage door opener back up and running quickly once you have determined it needs to be replaced\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with models: 1020L, 2020L, GCG350, GCG350L, GCG350ML, H2000C-1, H2000C, PCG500ML, PCG700ML, PCG700FN, H2000C-1\u003c\/li\u003e\n\u003cli\u003eGenuine Genie replacement part \u003c\/li\u003e\n\u003cli\u003eComes with installation instructions for DIY replacement\u003c\/li\u003e\n\u003cli\u003eRequires remote and limit re-programming with the new replacement board (see the instructions for details) \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- TABS --\u003e\n\u003ch5\u003eReviews\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eInstallation Instructions\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/36190S.S_Relacement_Circuit_Board_Instructions.pdf?4224\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/PDF_ICON_icon.png?v=1533737947\" alt=\"\"\u003e PDF Instructions for replacing the 36190S.S control board \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eBelow are two sets of instructions depending on which model garage door opener you have that you are replacing the 36190S.S circuit board on. The first set is for Chan Glide Models, below that is for Chain Drive Models. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e36190S CONTROL BOARD INSTALLATION INSTRUCTIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReplacing the control board for CHAIN GLIDE MODELS\u003c\/strong\u003e\u003cbr\u003eGCG 350\/350L\/350ML, PCG 400\/450\/500ML\/600\/650\/700ML OCG 510\/550\/600ML\/710\/750\/800ML\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTools Required:\u003c\/strong\u003e 1\/4” nut driver or socket, Phillips and straight blade screwdriver.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. UNPLUG\u003c\/strong\u003e operator from 110V outlet (if the unit is permanently wired, shut off power to the unit). Open light lens and remove with motor cover (one screw) to expose control board, Fig. 1.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. REMOVE\u003c\/strong\u003e wall control, photocell and limit switch leads (on ML models) from front terminal strip, Fig. 2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. REMOVE\u003c\/strong\u003e rear control board mounting bracket and 2 mounting screws at top edge of control board, Fig. 3.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. UNPLUG\u003c\/strong\u003e wire harness and remove existing control board, Fig. 4.\u003cbr\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e ML models do not require the following modification of the front panel as shown, Fig. 5.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. REMOVE\u003c\/strong\u003e the three knockout covers in terminal positions 4, 5 and 6 with the straight screwdriver, Fig. 5. They must be removed to make room for the additional terminals on the new board (used only on ML models).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. RE-CONNECT\u003c\/strong\u003e wire harness and replace with the new 36190S.S control board. Make sure board is properly seated in the front panel support details and replace the mounting bracket. Securely tighten screw. Replace mounting screws at top edge and tighten snugly (DO NOT OVER-TIGHTEN. This can cause the board to crack).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e7. REPLACE\u003c\/strong\u003e motor cover and light lens.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e8. RE-CONNECT\u003c\/strong\u003e wall control, photocell and limit switch leads. Do this BEFORE re-connecting main power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e9. REPLACE\u003c\/strong\u003e the motor cover. (Control boards can be light sensitive and should not be operated while uncovered.)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e10. PLUG IN\u003c\/strong\u003e power cord to 110V outlet (or reset breaker).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e11. ADJUST\u003c\/strong\u003e up and down force controls and program transmitter devices per the owner’s manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e ChainGlide models do\u003cstrong\u003e NOT\u003c\/strong\u003e require the use of the limit switch key cap included with this kit. \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/36190S.S_Relacement_Circuit_Board_Instructions_Section_1_large.png?v=1559150753\" alt=\"Replacing the Genie Control Board 36190S.S for ChainGlide models \"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e36190S.S Control Board Installation Instructions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement Board for CHAIN DRIVE MODELS \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIC 250B, PMX 300\/500 ICB, 496\/696 CD\/B\u003c\/p\u003e\n\u003cp\u003eTools Required: 1\/4” nut driver or socket, straight blade screwdriver.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. UNPLUG\u003c\/strong\u003e operator from 110V outlet (if the unit is permanently wired, shut off the power to the unit) and remove side cover (4 screws) to expose control board, Fig. 1.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. REMOVE\u003c\/strong\u003e wall control and photocell leads from terminal strip, Fig. 2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. REMOVE\u003c\/strong\u003e control board mounting bracket at right edge of control board and 2 small mounting clips at top edge, Fig. 3.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. UNPLUG\u003c\/strong\u003e wire harness and remove existing control board, Fig. 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. INSTALL\u003c\/strong\u003e control board mounting clips and limit switch key cap on replacement board, Fig. 5.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. REMOVE\u003c\/strong\u003e the three knockout covers in terminal positions 4, 5 and 6 with the screwdriver, Fig. 6. They must be removed to make room for the additional terminals on the new board (used only on other models).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e7. RE-CONNECT\u003c\/strong\u003e wire harness and replace control board. Make sure board is properly seated in the rear panel support details and replace the mounting bracket. Securely tighten screw. Replace screws in mounting clips and tighten snugly (DO NOT OVER-TIGHTEN. This can cause the clips to crack).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e8. REPLACE\u003c\/strong\u003e side cover. (Control boards can be light sensitive and should not be operated while uncovered.)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e9. RE-CONNECT\u003c\/strong\u003e wall control and photocell leads. Do this BEFORE re-connecting main power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e10. PLUG IN\u003c\/strong\u003e power cord to 110V outlet (or reset breaker).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e11. ADJUST\u003c\/strong\u003e up and downforce controls and program transmitter devices per the owner’s manual.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/36190S.S_Relacement_Circuit_Board_Instructions_Section_2_large.png?v=1559151000\" alt=\"36190S.S Genie control board replacement for chain drive models \"\u003e\u003c\/p\u003e\n\u003c!-- \/TABS --\u003e","published_at":"2017-06-26T15:54:10-04:00","created_at":"2017-06-26T15:55:36-04:00","vendor":"The Genie Company","type":"Service Parts","tags":["Circuit Board"],"price":9303,"price_min":9303,"price_max":9303,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41470208963,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"36190S.S","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Control Board (6 Terminal Board) 36190S.S","public_title":null,"options":["Default Title"],"price":9303,"weight":363,"compare_at_price":null,"inventory_quantity":999,"inventory_management":"shopify","inventory_policy":"continue","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/products\/36190S.S-Board-F.jpg?v=1555443165","\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/products\/36190S.S-Board-T.jpg?v=1555443182"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/products\/36190S.S-Board-F.jpg?v=1555443165","options":["Title"],"content":"\u003cp\u003eConfigured circuit board for Chain Glide openers that have 6 terminals strip (models that have magnetic limits). This 6 terminal control board will get your garage door opener back up and running quickly once you have determined it needs to be replaced\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with models: 1020L, 2020L, GCG350, GCG350L, GCG350ML, H2000C-1, H2000C, PCG500ML, PCG700ML, PCG700FN, H2000C-1\u003c\/li\u003e\n\u003cli\u003eGenuine Genie replacement part \u003c\/li\u003e\n\u003cli\u003eComes with installation instructions for DIY replacement\u003c\/li\u003e\n\u003cli\u003eRequires remote and limit re-programming with the new replacement board (see the instructions for details) \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- TABS --\u003e\n\u003ch5\u003eReviews\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eInstallation Instructions\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/36190S.S_Relacement_Circuit_Board_Instructions.pdf?4224\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/PDF_ICON_icon.png?v=1533737947\" alt=\"\"\u003e PDF Instructions for replacing the 36190S.S control board \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eBelow are two sets of instructions depending on which model garage door opener you have that you are replacing the 36190S.S circuit board on. The first set is for Chan Glide Models, below that is for Chain Drive Models. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e36190S CONTROL BOARD INSTALLATION INSTRUCTIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReplacing the control board for CHAIN GLIDE MODELS\u003c\/strong\u003e\u003cbr\u003eGCG 350\/350L\/350ML, PCG 400\/450\/500ML\/600\/650\/700ML OCG 510\/550\/600ML\/710\/750\/800ML\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTools Required:\u003c\/strong\u003e 1\/4” nut driver or socket, Phillips and straight blade screwdriver.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. UNPLUG\u003c\/strong\u003e operator from 110V outlet (if the unit is permanently wired, shut off power to the unit). Open light lens and remove with motor cover (one screw) to expose control board, Fig. 1.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. REMOVE\u003c\/strong\u003e wall control, photocell and limit switch leads (on ML models) from front terminal strip, Fig. 2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. REMOVE\u003c\/strong\u003e rear control board mounting bracket and 2 mounting screws at top edge of control board, Fig. 3.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. UNPLUG\u003c\/strong\u003e wire harness and remove existing control board, Fig. 4.\u003cbr\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e ML models do not require the following modification of the front panel as shown, Fig. 5.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. REMOVE\u003c\/strong\u003e the three knockout covers in terminal positions 4, 5 and 6 with the straight screwdriver, Fig. 5. They must be removed to make room for the additional terminals on the new board (used only on ML models).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. RE-CONNECT\u003c\/strong\u003e wire harness and replace with the new 36190S.S control board. Make sure board is properly seated in the front panel support details and replace the mounting bracket. Securely tighten screw. Replace mounting screws at top edge and tighten snugly (DO NOT OVER-TIGHTEN. This can cause the board to crack).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e7. REPLACE\u003c\/strong\u003e motor cover and light lens.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e8. RE-CONNECT\u003c\/strong\u003e wall control, photocell and limit switch leads. Do this BEFORE re-connecting main power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e9. REPLACE\u003c\/strong\u003e the motor cover. (Control boards can be light sensitive and should not be operated while uncovered.)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e10. PLUG IN\u003c\/strong\u003e power cord to 110V outlet (or reset breaker).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e11. ADJUST\u003c\/strong\u003e up and down force controls and program transmitter devices per the owner’s manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e ChainGlide models do\u003cstrong\u003e NOT\u003c\/strong\u003e require the use of the limit switch key cap included with this kit. \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/36190S.S_Relacement_Circuit_Board_Instructions_Section_1_large.png?v=1559150753\" alt=\"Replacing the Genie Control Board 36190S.S for ChainGlide models \"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e36190S.S Control Board Installation Instructions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement Board for CHAIN DRIVE MODELS \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIC 250B, PMX 300\/500 ICB, 496\/696 CD\/B\u003c\/p\u003e\n\u003cp\u003eTools Required: 1\/4” nut driver or socket, straight blade screwdriver.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. UNPLUG\u003c\/strong\u003e operator from 110V outlet (if the unit is permanently wired, shut off the power to the unit) and remove side cover (4 screws) to expose control board, Fig. 1.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. REMOVE\u003c\/strong\u003e wall control and photocell leads from terminal strip, Fig. 2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. REMOVE\u003c\/strong\u003e control board mounting bracket at right edge of control board and 2 small mounting clips at top edge, Fig. 3.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. UNPLUG\u003c\/strong\u003e wire harness and remove existing control board, Fig. 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. INSTALL\u003c\/strong\u003e control board mounting clips and limit switch key cap on replacement board, Fig. 5.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. REMOVE\u003c\/strong\u003e the three knockout covers in terminal positions 4, 5 and 6 with the screwdriver, Fig. 6. They must be removed to make room for the additional terminals on the new board (used only on other models).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e7. RE-CONNECT\u003c\/strong\u003e wire harness and replace control board. Make sure board is properly seated in the rear panel support details and replace the mounting bracket. Securely tighten screw. Replace screws in mounting clips and tighten snugly (DO NOT OVER-TIGHTEN. This can cause the clips to crack).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e8. REPLACE\u003c\/strong\u003e side cover. (Control boards can be light sensitive and should not be operated while uncovered.)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e9. RE-CONNECT\u003c\/strong\u003e wall control and photocell leads. Do this BEFORE re-connecting main power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e10. PLUG IN\u003c\/strong\u003e power cord to 110V outlet (or reset breaker).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e11. ADJUST\u003c\/strong\u003e up and downforce controls and program transmitter devices per the owner’s manual.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/36190S.S_Relacement_Circuit_Board_Instructions_Section_2_large.png?v=1559151000\" alt=\"36190S.S Genie control board replacement for chain drive models \"\u003e\u003c\/p\u003e\n\u003c!-- \/TABS --\u003e"}

Control Board (6 Terminal Board) 36190S.S

Product Description
$93.03
Maximum quantity available reached.

Configured circuit board for Chain Glide openers that have 6 terminals strip (models that have magnetic limits). This 6 terminal control board will get your garage door opener back up and running quickly once you have determined it needs to be replaced.

  • Compatible with models: 1020L, 2020L, GCG350, GCG350L, GCG350ML, H2000C-1, H2000C, PCG500ML, PCG700ML, PCG700FN, H2000C-1
  • Genuine Genie replacement part 
  • Comes with installation instructions for DIY replacement
  • Requires remote and limit re-programming with the new replacement board (see the instructions for details) 
Sku: 36190S.S

 PDF Instructions for replacing the 36190S.S control board 

Below are two sets of instructions depending on which model garage door opener you have that you are replacing the 36190S.S circuit board on. The first set is for Chan Glide Models, below that is for Chain Drive Models. 

36190S CONTROL BOARD INSTALLATION INSTRUCTIONS

Replacing the control board for CHAIN GLIDE MODELS
GCG 350/350L/350ML, PCG 400/450/500ML/600/650/700ML OCG 510/550/600ML/710/750/800ML

Tools Required: 1/4” nut driver or socket, Phillips and straight blade screwdriver.

1. UNPLUG operator from 110V outlet (if the unit is permanently wired, shut off power to the unit). Open light lens and remove with motor cover (one screw) to expose control board, Fig. 1.

2. REMOVE wall control, photocell and limit switch leads (on ML models) from front terminal strip, Fig. 2.

3. REMOVE rear control board mounting bracket and 2 mounting screws at top edge of control board, Fig. 3.

4. UNPLUG wire harness and remove existing control board, Fig. 4.
NOTE: ML models do not require the following modification of the front panel as shown, Fig. 5.

5. REMOVE the three knockout covers in terminal positions 4, 5 and 6 with the straight screwdriver, Fig. 5. They must be removed to make room for the additional terminals on the new board (used only on ML models).

6. RE-CONNECT wire harness and replace with the new 36190S.S control board. Make sure board is properly seated in the front panel support details and replace the mounting bracket. Securely tighten screw. Replace mounting screws at top edge and tighten snugly (DO NOT OVER-TIGHTEN. This can cause the board to crack).

7. REPLACE motor cover and light lens.

8. RE-CONNECT wall control, photocell and limit switch leads. Do this BEFORE re-connecting main power.

9. REPLACE the motor cover. (Control boards can be light sensitive and should not be operated while uncovered.)

10. PLUG IN power cord to 110V outlet (or reset breaker).

11. ADJUST up and down force controls and program transmitter devices per the owner’s manual.

NOTE: ChainGlide models do NOT require the use of the limit switch key cap included with this kit. 

Replacing the Genie Control Board 36190S.S for ChainGlide models

 

36190S.S Control Board Installation Instructions

Replacement Board for CHAIN DRIVE MODELS 

IC 250B, PMX 300/500 ICB, 496/696 CD/B

Tools Required: 1/4” nut driver or socket, straight blade screwdriver.

1. UNPLUG operator from 110V outlet (if the unit is permanently wired, shut off the power to the unit) and remove side cover (4 screws) to expose control board, Fig. 1.

2. REMOVE wall control and photocell leads from terminal strip, Fig. 2.

3. REMOVE control board mounting bracket at right edge of control board and 2 small mounting clips at top edge, Fig. 3.

4. UNPLUG wire harness and remove existing control board, Fig. 4.

5. INSTALL control board mounting clips and limit switch key cap on replacement board, Fig. 5.

6. REMOVE the three knockout covers in terminal positions 4, 5 and 6 with the screwdriver, Fig. 6. They must be removed to make room for the additional terminals on the new board (used only on other models).

7. RE-CONNECT wire harness and replace control board. Make sure board is properly seated in the rear panel support details and replace the mounting bracket. Securely tighten screw. Replace screws in mounting clips and tighten snugly (DO NOT OVER-TIGHTEN. This can cause the clips to crack).

8. REPLACE side cover. (Control boards can be light sensitive and should not be operated while uncovered.)

9. RE-CONNECT wall control and photocell leads. Do this BEFORE re-connecting main power.

10. PLUG IN power cord to 110V outlet (or reset breaker).

11. ADJUST up and downforce controls and program transmitter devices per the owner’s manual.

36190S.S Genie control board replacement for chain drive models

Questions & Answers

Ask a Question
  • I have a genie 2020 opener. Need a new circuit board. Looks like the part number is 35917 on the board but I don’t see it listed in your replacement parts. Please advise.

    The Genie 2020L model garage door opener uses the 36190S.S circuit board.