{"id":302406271016,"title":"Wall Console for Series III Product","handle":"copy-of-wall-console-for-series-ii-product","description":"\u003cp\u003eMulti-function wired wall console with open\/close, light and vacation lock buttons. There is a red led light in the wall console that lights up to help locate the wall console in the dark. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eONLY compatible with Models 3022, 3024, 3042, 4022, 4024 \u0026amp; 4042 that have a serial number LOWER than the number 122494110518\u003c\/li\u003e\n\u003cli\u003eCircuit board inside the operator must start with the '37470R' prefix\u003c\/li\u003e\n\u003cli\u003eUse this Series III wall console to directly add to or replace another Series III wall console of the exact same design and coloring \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/store.geniecompany.com\/pages\/proposition-65\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/trianglewarning_icon.jpg?v=1529498861\" alt=\"\" width=\"19\" height=\"19\"\u003e California\u003cspan\u003e Residents: \u003c\/span\u003eProposition 65 WARNING\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- TABS --\u003e\n\u003ch5\u003eReviews\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eInstallation Instructions\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.geniecompany.com\/data\/products\/accessories\/manuals\/legacy\/37222R_37254500131.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/PDF_ICON_icon.png?v=1533737947\" alt=\"\"\u003e PDF Series III Wall Console Installation Instructions \u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeries III Replacement Wall Console, 37222R Installation \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. IMPORTANT INFORMATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse only the Series III wall console with Genie® garage door\u003cbr\u003eopeners models 2562, 2564, 3022, 3024, 3042, 3062, 3064, 4022,\u003cbr\u003e4024, 4042, 4062, and 4064 that were from 2010 through 2012 with Series III electronics. The serial number will be lower than \u003cspan\u003e122494110518. \u003c\/span\u003e If you currently have a series III wall console and have not replaced the circuit board, this will work. If you are unsure, please contact Genie customer service at 1-800-354-3643. \u003c\/p\u003e\n\u003cp\u003eSERIES III WALL CONSOLE - OPERATION AND FEATURES\u003c\/p\u003e\n\u003cp\u003eWall console has three buttons and one indicator light.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37222R_Series_III_Wall_Console_Replacement_Instructions_Step_1_large.png?v=1559224873\" alt=\"Genie Series III Wall Console 37222R\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndicator Light\u003c\/strong\u003e\u003cbr\u003eIndicator light will display red when wall console is properly wired and Sure-Lock™ is OFF. When Sure-Lock™ is ON indicator light flashes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOpen\/Close Button\u003c\/strong\u003e\u003cbr\u003eUse this button to open or close garage door. When Sure- Lock™ is ON the Open\/Close button will CLOSE door only. Note: Constant button pressure in the CLOSE mode will override error responses in the powerhead and close door.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndependent Light Console Button\u003c\/strong\u003e\u003cbr\u003eUse this button to turn powerhead lights ON. Powerhead lighting will remain ON until this button is pressed again or a door action has been completed. Note: If opener has a Motion Detector, the sensor will keep powerhead lights ON as long as motion is detected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSure-Lock™ Button\u003c\/strong\u003e\u003cbr\u003eWhen Sure-Lock™ is ON the powerhead cannot be activated by the wall console or a remote.\u003cbr\u003e• Press and hold for 5 seconds (or until Indicator Light flashes) to activate Sure-Lock™.\u003cbr\u003e• Press and release to turn Sure-Lock™ OFF.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eWARNING \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Verify there is NO power to the opener before installing wall console and\/or wall console wires.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Use of any other wall console can cause the door to operate unexpectedly and the light not to work. Use only the included wall console.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eCAUTION\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Staples which are too tight can cut or pinch wires. Cut or pinched wires can cause the wall console to stop working. When using the insulated staples, make sure you fasten them only as tightly as needed to hold the wire snugly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37222R_Series_III_Wall_Console_Replacement_Instructions_Tools_Required_large.png?v=1559224830\" alt=\"Genie Series III Wall Console Tools Required for Installation \"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeries III Wall Console - Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse these instructions when replacing a Series III wall console.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. Install Replacement Wall Console\u003c\/strong\u003e\u003cbr\u003e• Disconnect power to powerhead.\u003cbr\u003e• Remove wires from existing wall console.\u003cbr\u003e• Split and strip ends of wire if required (Fig. 2).\u003cbr\u003e• Fasten wire to control board screws on back of wall console (Fig. 3).\u003cbr\u003e– Striped wire to the + (plus) terminal\u003cbr\u003e– White wire to the - (minus) terminal\u003cbr\u003e• Mount wall console to wall using screws provided.\u003cbr\u003e• Reconnect power to powerhead.\u003cbr\u003e• Check operation of each wall console button and feature.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37222R_Series_III_Wall_Console_Replacement_Instructions_Step_2_large.png?v=1559224957\" alt=\"Genie Series III Wall console replacement instructions \"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeries III Wall Console - Expansion\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse these instructions when you are expanding or adding to an existing Series III wall console.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. Wall Console Wiring (in series or in parallel)\u003c\/strong\u003e\u003cbr\u003e• Disconnect power to powerhead.\u003cbr\u003e• Pick a convenient location for mounting new wall console\u003cbr\u003eNOTE: Securely anchor wires to ceiling and wall using insulated staples (Fig. 5). Staples should be snug only.\u003cbr\u003e• (in series) Run wire from new wall console to existing wall console (Fig. 7).\u003cbr\u003e– Split and strip ends of wire (Fig. 2)\u003cbr\u003e– Fasten wire to control board screws on back of existing wall console.\u003cbr\u003eStriped wire to the + (plus) terminal\u003cbr\u003eWhite wire to the - (minus) terminal\u003cbr\u003e• (in parallel) Run wire from new wall console to powerhead (Fig. 8).\u003c\/p\u003e\n\u003cp\u003e– Route wire through wire guide on powerhead (Fig. 6)\u003cbr\u003e– Split and strip ends of wire (Fig. 2)\u003cbr\u003e– Insert wire into terminal holes and lightly press in the locking clips above each terminal hole (Fig. 8)\u003cbr\u003e– Confirm wire lock by lightly tugging on the wire. Wire should remain in the terminal hole.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Fasten wire to control board screws on back of new wall console (Fig. 3).\u003c\/strong\u003e\u003cbr\u003eStriped wire to the + (plus) terminal\u003cbr\u003eWhite wire to the - (minus) terminal\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Reconnect power to powerhead.\u003c\/strong\u003e\u003cbr\u003e• Check operation of each button and feature of both wall consoles.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37222R_Series_III_Wall_Console_Replacement_Instructions_Step_3_large.png?v=1559225135\" alt=\"37222R Genie Series III wall console installation, adding \"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/TABS --\u003e","published_at":"2017-08-22T16:50:42-04:00","created_at":"2017-11-30T13:20:02-05:00","vendor":"The Genie Company","type":"Wall Console","tags":["Series III","Wall Console"],"price":2699,"price_min":2699,"price_max":2699,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":3027210174504,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"37222R","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Wall Console for Series III Product","public_title":null,"options":["Default Title"],"price":2699,"weight":91,"compare_at_price":null,"inventory_quantity":999,"inventory_management":"shopify","inventory_policy":"continue","barcode":"050049017323"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/products\/37222R_Series_III_Black_Wall_Console.jpg?v=1540410087","\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/products\/37222R-Genie-Wall-Console-Series-3-21.jpg?v=1549473835","\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/products\/37222R-Genie-Wall-Console-Series-3-14.jpg?v=1549473866"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/products\/37222R_Series_III_Black_Wall_Console.jpg?v=1540410087","options":["Title"],"content":"\u003cp\u003eMulti-function wired wall console with open\/close, light and vacation lock buttons. There is a red led light in the wall console that lights up to help locate the wall console in the dark. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eONLY compatible with Models 3022, 3024, 3042, 4022, 4024 \u0026amp; 4042 that have a serial number LOWER than the number 122494110518\u003c\/li\u003e\n\u003cli\u003eCircuit board inside the operator must start with the '37470R' prefix\u003c\/li\u003e\n\u003cli\u003eUse this Series III wall console to directly add to or replace another Series III wall console of the exact same design and coloring \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/store.geniecompany.com\/pages\/proposition-65\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/trianglewarning_icon.jpg?v=1529498861\" alt=\"\" width=\"19\" height=\"19\"\u003e California\u003cspan\u003e Residents: \u003c\/span\u003eProposition 65 WARNING\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- TABS --\u003e\n\u003ch5\u003eReviews\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eInstallation Instructions\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.geniecompany.com\/data\/products\/accessories\/manuals\/legacy\/37222R_37254500131.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/PDF_ICON_icon.png?v=1533737947\" alt=\"\"\u003e PDF Series III Wall Console Installation Instructions \u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeries III Replacement Wall Console, 37222R Installation \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. IMPORTANT INFORMATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse only the Series III wall console with Genie® garage door\u003cbr\u003eopeners models 2562, 2564, 3022, 3024, 3042, 3062, 3064, 4022,\u003cbr\u003e4024, 4042, 4062, and 4064 that were from 2010 through 2012 with Series III electronics. The serial number will be lower than \u003cspan\u003e122494110518. \u003c\/span\u003e If you currently have a series III wall console and have not replaced the circuit board, this will work. If you are unsure, please contact Genie customer service at 1-800-354-3643. \u003c\/p\u003e\n\u003cp\u003eSERIES III WALL CONSOLE - OPERATION AND FEATURES\u003c\/p\u003e\n\u003cp\u003eWall console has three buttons and one indicator light.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37222R_Series_III_Wall_Console_Replacement_Instructions_Step_1_large.png?v=1559224873\" alt=\"Genie Series III Wall Console 37222R\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndicator Light\u003c\/strong\u003e\u003cbr\u003eIndicator light will display red when wall console is properly wired and Sure-Lock™ is OFF. When Sure-Lock™ is ON indicator light flashes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOpen\/Close Button\u003c\/strong\u003e\u003cbr\u003eUse this button to open or close garage door. When Sure- Lock™ is ON the Open\/Close button will CLOSE door only. Note: Constant button pressure in the CLOSE mode will override error responses in the powerhead and close door.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndependent Light Console Button\u003c\/strong\u003e\u003cbr\u003eUse this button to turn powerhead lights ON. Powerhead lighting will remain ON until this button is pressed again or a door action has been completed. Note: If opener has a Motion Detector, the sensor will keep powerhead lights ON as long as motion is detected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSure-Lock™ Button\u003c\/strong\u003e\u003cbr\u003eWhen Sure-Lock™ is ON the powerhead cannot be activated by the wall console or a remote.\u003cbr\u003e• Press and hold for 5 seconds (or until Indicator Light flashes) to activate Sure-Lock™.\u003cbr\u003e• Press and release to turn Sure-Lock™ OFF.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eWARNING \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Verify there is NO power to the opener before installing wall console and\/or wall console wires.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Use of any other wall console can cause the door to operate unexpectedly and the light not to work. Use only the included wall console.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eCAUTION\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e• Staples which are too tight can cut or pinch wires. Cut or pinched wires can cause the wall console to stop working. When using the insulated staples, make sure you fasten them only as tightly as needed to hold the wire snugly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37222R_Series_III_Wall_Console_Replacement_Instructions_Tools_Required_large.png?v=1559224830\" alt=\"Genie Series III Wall Console Tools Required for Installation \"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeries III Wall Console - Replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse these instructions when replacing a Series III wall console.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. Install Replacement Wall Console\u003c\/strong\u003e\u003cbr\u003e• Disconnect power to powerhead.\u003cbr\u003e• Remove wires from existing wall console.\u003cbr\u003e• Split and strip ends of wire if required (Fig. 2).\u003cbr\u003e• Fasten wire to control board screws on back of wall console (Fig. 3).\u003cbr\u003e– Striped wire to the + (plus) terminal\u003cbr\u003e– White wire to the - (minus) terminal\u003cbr\u003e• Mount wall console to wall using screws provided.\u003cbr\u003e• Reconnect power to powerhead.\u003cbr\u003e• Check operation of each wall console button and feature.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37222R_Series_III_Wall_Console_Replacement_Instructions_Step_2_large.png?v=1559224957\" alt=\"Genie Series III Wall console replacement instructions \"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeries III Wall Console - Expansion\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse these instructions when you are expanding or adding to an existing Series III wall console.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. Wall Console Wiring (in series or in parallel)\u003c\/strong\u003e\u003cbr\u003e• Disconnect power to powerhead.\u003cbr\u003e• Pick a convenient location for mounting new wall console\u003cbr\u003eNOTE: Securely anchor wires to ceiling and wall using insulated staples (Fig. 5). Staples should be snug only.\u003cbr\u003e• (in series) Run wire from new wall console to existing wall console (Fig. 7).\u003cbr\u003e– Split and strip ends of wire (Fig. 2)\u003cbr\u003e– Fasten wire to control board screws on back of existing wall console.\u003cbr\u003eStriped wire to the + (plus) terminal\u003cbr\u003eWhite wire to the - (minus) terminal\u003cbr\u003e• (in parallel) Run wire from new wall console to powerhead (Fig. 8).\u003c\/p\u003e\n\u003cp\u003e– Route wire through wire guide on powerhead (Fig. 6)\u003cbr\u003e– Split and strip ends of wire (Fig. 2)\u003cbr\u003e– Insert wire into terminal holes and lightly press in the locking clips above each terminal hole (Fig. 8)\u003cbr\u003e– Confirm wire lock by lightly tugging on the wire. Wire should remain in the terminal hole.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Fasten wire to control board screws on back of new wall console (Fig. 3).\u003c\/strong\u003e\u003cbr\u003eStriped wire to the + (plus) terminal\u003cbr\u003eWhite wire to the - (minus) terminal\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Reconnect power to powerhead.\u003c\/strong\u003e\u003cbr\u003e• Check operation of each button and feature of both wall consoles.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1470\/8272\/files\/37222R_Series_III_Wall_Console_Replacement_Instructions_Step_3_large.png?v=1559225135\" alt=\"37222R Genie Series III wall console installation, adding \"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- \/TABS --\u003e"}
Wall Console for Series III Product ,  Wall Console - The Genie Company

Wall Console for Series III Product

$26.99

Multi-function wired wall console with open/close, light and vacation lock buttons. There is a red led light in the wall console that lights up to help locate the wall console in the dark.  ONLY compatible with Models 3022, 3024, 3042, 4022, 4024 & 4042 that have a serial number LOWER than the number 122494110518 Circuit board inside the op...


More Info