Free Shipping on all U.S. Orders $17.99+

Sequencer Board 20386R.S

Product Description
$79.99
Maximum quantity available reached.

Sequencer circuit board for screw drive model openers. Use this board to get your opener back up and running quickly if you have determined your circuit board needs to be replaced.

  • Compatible with models IS525, IS550, IS850, IS900, IS900, IS920, CM7600, CM8600, PRO95, PRO95FN, CM8600-FN, H4000, H6000, 2060L, 2060L-07, 3060L, 3060L-07, IMS1000, ISL950, ISL950, ISL980, ISL980, 2560, 3560, 1060, 1560, 3860 Please note: NOT compatible with "/B" units
  • Replaces old board part number 31184R
  • Genuine Genie replacement part 
  • Requires re-programming with the new board 
Sku: 20386R.S

QUESTIONS & ANSWERS

Ask a Question
  • Wil this work with the H6000-07/M?

    Yes, it is compatible.

  • Will this work for model IS900/A??? Apparently the “learn” button in mine is bad and need to replace.

    Yes, it will!

  • Hi I recently started having a problem with the H4000A door opener,opening and closing itself . My first impression was one of the 2 remotes was failing so I disconnected the wireless board . That didn't fix the problem so I next disconnected the wall push button assuming it was bad, that didn't seem to be the problem either so I next disconnected the push button wire at the unit , and I did not hook up the wireless remote board or wires to the wall push button again during these diagnostic tests . The unit still seemed to have a mind of it's own which leads me to believe that something on the sequencer board is failing at the component level. I'd like to also add that I am a retired electrician. I guess my question to you at this point is what is your opinion as to the problem at this point.I really don't want to spend the money for a new unit if this one can be repaired . Thank you

    If you alrady disconnected the wall console, the wall console wires, and all of the wireless devices as you have mentioned, then yes, the sequencer board would need to be replaced to fix this issue.

  • will this solve the problem of lights staying on

    Constant light could be caused by a few different things. In order to eliminate these, here are a few steps to try.

    First you would want to remove the wall button from the wall. Then take the two wires off the back of it and leave them off.

    You would then want to run the unit with a remote, then wait at least five minutes and the light should time out. If they do go out, you would want to replace the wall console. 

    If they do not, then you would want to remove the wall button wires from the power head. Again, run the unit with a remote, wait the five minutes and see if they go out. If they do, you would want to replace the wall button wire from the wall button to the power head. (This is 18 to 22 gauge doorbell wire)

    If they do not go out after both of these then this circuit board would need to be replaced in the unit.

  • Will this work for model sd 8000

    No, it will not.

  • Hi When you press the remote the garage door goes up about a foot and then stops. after hitting the button several more times it seems to work again. can you tell me the problem?

    The force of the garage door opener may need to be adjusted. What model is your garage door opener?

  • Will this board work for an H4000A ?

    Yes, it will.

  • do you have a compatible sequencer bd to replace a W-21593-A

    Do you know what model the garage door opener is?

  • Will this work for gx9000 opener if not which one will

    No, it will not. We no longer have a circuit board for the GX9000 model garage door opener.

  • Is it compatible with H4000-07? And if it is not the piece that it needs, can I return it?

    Yes, this will work on the H4000-07 garage door opener. Once the circuit board is installed, it cannot be returned. Please see our return policy. If you need help troubleshooting the issue you have with your garage door opener, we would be happy to help. You can contact Genie customer service at 1-800-354-3643.

  • I have Blue Max Screw Drive opener. The light is not coming ON. Checked bulb, socket. No click sound when opener unit is plugged and unplugged. So, assuming that the circuit board or light relay is faulty. What do you suggest to fix it? Thanks.

    Please contact Genie customer service at 1-800-354-3643 for troubleshooting assistance.

  • Will this work with the PMX5001C opener

    No, it will not. The PMX500/IC-B model would need the 36190T.S circuit board.